Objectives-To investigate the validity and reliability of surface electromyography (EMG) as a new non-invasive determinant of the metabolic response to incremental exercise in elite cyclists. The relation between EMG activity and other more conventional methods for analysing the aerobic-anaerobic transition such as blood lactate measurements (lactate threshold (LT) and onset of blood lactate accumulation (OBLA)) and ventilatory parameters (ventilatory thresholds 1 and 2 (VT 1 and VT 2 )) was studied. Methods-Twenty eight elite road cyclists (age 24 (4) years; Ṽ O 2 MAX 69.9 (6.4) ml/kg/min; values mean (SD)) were selected as subjects. Each of them performed a ramp protocol (starting at 0 W, with increases of 5 W every 12 seconds) on a cycle ergometer (validity study). In addition, 15 of them performed the same test twice (reliability study). During the tests, data on gas exchange and blood lactate levels were collected to determine VT 1 , VT 2 , LT, and OBLA. The root mean squares of EMG signals (rms-EMG) were recorded from both the vastus lateralis and the rectus femoris at each intensity using surface electrodes. Results-A two threshold response was detected in the rms-EMG recordings from both muscles in 90% of subjects, with two breakpoints, EMG T1 and EMG T2 , at around 60-70% and 80-90% of Ṽ O 2 MAX respectively. The results of the reliability study showed no significant diVerences (p>0.05) between mean values of EMG T1 and EMG T2 obtained in both tests. Furthermore, no significant diVerences (p>0.05) existed between mean values of EMG T1 , in the vastus lateralis and rectus femoris, and VT 1 and LT (62.8 (14.5) and 69.0 (6.2) and 64.6 (6.4) and 68.7 (8.2)% of Ṽ O 2 MAX respectively), or between mean values of EMG T2 , in the vastus lateralis and rectus femoris, and VT 2 and OBLA (86.9 (9.0) and 88.0 (6.2) and 84.6 (6.5) and 87.7 (6.4)% of v O 2 MAX respectively). Conclusion-rms-EMG may be a useful complementary non-invasive method for analysing the aerobic-anaerobic transition (ventilatory and lactate thresholds) in elite cyclists. (Br J Sports Med 1999;33:178-185)
Background-Acute thrombogenicity and re-endothelialization represent clinically relevant end points pertaining to the safety of coronary stents, which have not been compared among biodegradable polymer-based drug-eluting metallic stents and fully bioabsorbable scaffolds to date. Methods and Results-We investigated comparative outcomes with respect to acute thrombogenicity and re-endothelialization among thin-strut biodegradable polymer metallic everolimus eluting stents (EES), thick-strut fully bioabsorbable EES, thick-strut biodegradable polymer metallic biolimus-eluting stents and control bare metal stents. An ex-vivo porcine arterio-venous shunt model was used to assess platelet aggregation, whereas a healthy rabbit model of iliofemoral stent implantation was used to assess re-endothelialization and inflammation. Confocal microscopy was used to detect fluorescently labeled antibody staining directed against CD61/CD42b for the identification of aggregated thrombocytes, CD14/PM-1, and RAM-11 for identification of neutrophils and monocytes/macrophages. Endothelial recovery was assessed by scanning electron microscopy, whereas CD31/PECAM-1 was used to confirm endothelial maturity. EES demonstrated significantly less acute thrombogenicity compared with bioabsorbable EES and biolimus-eluting stents. EES showed greater re-endothelialization at 28 days and reduced inflammatory cell adhesion of monocytes/macrophages at 14 days compared with bioabsorbable EES. Only bare metal stents showed complete re-endothelialization at 28 days. Conclusions-These outcomes indicate differential trends in thrombogenicity and vascular healing among contemporary stents used in clinical practice and suggest a need for long-term adjunct antithrombotic pharmacotherapy for bioabsorbable EES. (Circ Cardiovasc Interv. 2015;8:e002427.
In this small study of patients undergoing MitraClip treatment with cerebral protection, embolic debris potentially conducive to cerebrovascular events was found in all patients. Debris was composed most often of acute thrombus, foreign material likely originating from the hydrophilic device coating, and valve/atrial wall tissue. Further studies are warranted to assess the impact of cerebral protection on the incidence of cerebrovascular events after MitraClip therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.