Optical clocks show unprecedented accuracy, surpassing that of previously available clock systems by more than one order of magnitude. Precise intercomparisons will enable a variety of experiments, including tests of fundamental quantum physics and cosmology and applications in geodesy and navigation. Well-established, satellite-based techniques for microwave dissemination are not adequate to compare optical clocks. Here, we present phase-stabilized distribution of an optical frequency over 920 kilometers of telecommunication fiber. We used two antiparallel fiber links to determine their fractional frequency instability (modified Allan deviation) to 5 × 10(-15) in a 1-second integration time, reaching 10(-18) in less than 1000 seconds. For long integration times τ, the deviation from the expected frequency value has been constrained to within 4 × 10(-19). The link may serve as part of a Europe-wide optical frequency dissemination network.
We have measured the frequency of the extremely narrow 1S-2S two-photon transition in atomic hydrogen using a remote cesium fountain clock with the help of a 920 km stabilized optical fiber. With an improved detection method we obtain f(1S-2S)=2466 061 413 187 018 (11) Hz with a relative uncertainty of 4.5×10(-15), confirming our previous measurement obtained with a local cesium clock [C. G. Parthey et al., Phys. Rev. Lett. 107, 203001 (2011)]. Combining these results with older measurements, we constrain the linear combinations of Lorentz boost symmetry violation parameters c((TX))=(3.1±1.9)×10(-11) and 0.92c((TY))+0.40c((TZ))=(2.6±5.3)×10(-11) in the standard model extension framework [D. Colladay, V. A. Kostelecký, Phys. Rev. D. 58, 116002 (1998)].
We demonstrate the long-distance transmission of an ultrastable optical frequency derived directly from a state-of-the-art optical frequency standard. Using an active stabilization system we deliver the frequency via a 146-km-long underground fiber link with a fractional instability of 3 x 10(-15) at 1 s, which is close to the theoretical limit for our transfer experiment. After 30,000 s, the relative uncertainty for the transfer is at the level of 1 x 10(-19). Tests with a very short fiber show that noise in our stabilization system contributes fluctuations that are 2 orders of magnitude lower, namely, 3 x 10(-17) at 1 s, reaching 10(-20) after 4,000 s.
We describe the use of fiber Brillouin amplification (FBA) for the coherent transmission of optical frequencies over a 480 km long optical fiber link. FBA uses the transmission fiber itself for efficient, bi-directional coherent amplification of weak signals with pump powers around 30 mW. In a test setup we measured the gain and the achievable signal-to-noise ratio (SNR) of FBA and compared it to that of the widely used uni-directional Erbium doped fiber amplifiers (EDFA) and to our recently built bi-directional EDFA. We measured also the phase noise introduced by the FBA and used a new and simple technique to stabilize the frequency of the FBA pump laser. We then transferred a stabilized laser frequency over a wide area network with a total fiber length of 480 km using only one intermediate FBA station. After compensating the noise induced by the fiber, the frequency is delivered to the user end with an uncertainty below 2 x 10(-18) and an instability sigma y(tau) = 2 x 10(-14) /(tau/s).
We report a bound on the relative frequency fluctuations in nonlinear second harmonic generation. A 1064 nm Nd:YAG laser is used to read out the phase of a Mach-Zehnder interferometer while PPKTP, a nonlinear crystal, is placed in each arm to generate second harmonic light. By comparing the arm length difference of the Mach Zehnder as read out by the fundamental 1064 nm light, and its second harmonic at 532 nm, we can bound the excess frequency noise introduced in the harmonic generation process. We report an amplitude spectral density of frequency noise with total RMS frequency deviation of 3 mHz and a minimum value of 20 µHz/Hz 1/2 over 250 seconds with a measurement bandwidth of 128 Hz, corresponding to an Allan deviation of 10 −19 at 20 seconds.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.