The detection of organic molecules is important in many areas, including medicine, environmental monitoring and defence. Stochastic sensing is an approach that relies on the observation of individual binding events between analyte molecules and a single receptor. Engineered transmembrane protein pores are promising sensor elements for stochastic detection, and in their simplest manifestation they produce a fluctuating binary ('on/off') response in the transmembrane electrical current. The frequency of occurrence of the fluctuations reveals the concentration of the analyte, and its identity can be deduced from the characteristic magnitude and/or duration of the fluctuations. Genetically engineered versions of the bacterial pore-forming protein alpha-haemolysin have been used to identify and quantify divalent metal ions in solution. But it is not immediately obvious how versatile binding sites for organic ligands might be obtained by engineering of the pore structure. Here we show that stochastic sensing of organic molecules can be procured from alpha-haemolysin by equipping the channel with an internal, non-covalently bound molecular 'adapter' which mediates channel blocking by the analyte. We use cyclodextrins as the adapters because these fit comfortably inside the pore and present a hydrophobic cavity suitable for binding a variety of organic analytes. Moreover, a single sensing element of this sort can be used to analyse a mixture of organic molecules with different binding characteristics. We envisage the use of other adapters, so that the pore could be 'programmed' for a range of sensing functions.
Here we describe a new type of biosensor element for detecting proteins in solution at nanomolar concentrations. We tethered a 3.4 kDa polyethylene glycol chain at a defined site within the lumen of the transmembrane protein pore formed by staphylococcal alpha-hemolysin. The free end of the polymer was covalently attached to a biotin molecule. On incorporation of the modified pore into a lipid bilayer, the biotinyl group moves from one side of the membrane to the other, and is detected by reversible capture with a mutant streptavidin. The capture events are observed as changes in ionic current passing through single pores in planar bilayers. Accordingly, the modified pore allows detection of a protein analyte at the single-molecule level, facilitating both quantification and identification through a distinctive current signature. The approach has higher time resolution compared with other kinetic measurements, such as those obtained by surface plasmon resonance.
SummaryGlucagon, secreted by pancreatic islet α cells, is the principal hyperglycemic hormone. In diabetes, glucagon secretion is not suppressed at high glucose, exacerbating the consequences of insufficient insulin secretion, and is inadequate at low glucose, potentially leading to fatal hypoglycemia. The causal mechanisms remain unknown. Here we show that α cell KATP-channel activity is very low under hypoglycemic conditions and that hyperglycemia, via elevated intracellular ATP/ADP, leads to complete inhibition. This produces membrane depolarization and voltage-dependent inactivation of the Na+ channels involved in action potential firing that, via reduced action potential height and Ca2+ entry, suppresses glucagon secretion. Maneuvers that increase KATP channel activity, such as metabolic inhibition, mimic the glucagon secretory defects associated with diabetes. Low concentrations of the KATP channel blocker tolbutamide partially restore glucose-regulated glucagon secretion in islets from type 2 diabetic organ donors. These data suggest that impaired metabolic control of the KATP channels underlies the defective glucose regulation of glucagon secretion in type 2 diabetes.
Engineered pores have several advantages as potential sensor elements: sensitivity is in the nanomolar range; analyte binding is rapid (diffusion limited in some cases) and reversible; strictly selective binding is not required because single-channel recordings are rich in information; and for a particular analyte, the dissociation rate constant, the extent of channel block and the voltage-dependence of these parameters are distinguishing, while the frequency of partial channel block reflects the analyte concentration. A single sensor element might, therefore, be used to quantitate more than one analyte at once. The approach described here can be generalized for additional analytes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.