It is still not fully understood how to predict the future prognosis of patients at the diagnosis coronavirus disease 2019 (COVID-19) due to the wide clinical range of the disease. We aimed to evaluate whether severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral load could predict the clinical course of pediatric patients. This study was conducted retrospectively with medical records of pediatric patients who were tested for SARS-CoV2 between April 12 and October 25, 2020 in the
Untreated ventricular septal defect (VSD) is an important cause of congestive heart failure in early infancy. Growth is impaired in this population, and surgical closure is challenging because of congestion in the lungs, making infants prone to respiratory infection, and because of their poor nutritional status. The aim of this study is to share our experience with percutaneous VSD closure in patients under 1 year of age. Patients with hemodynamically significant left-to-right shunt, less than 1 year of age, and with VSD diameter ≤ 6 mm were retrospectively included in the study between December 2014 and January 2017. The median length of follow-up was 8.5 (4-14.2) months. Twelve patients from 2 to 12 months of age, with a median weight of 6.75 (5.4-8) kg, were included. The mean VSD diameter as measured by angiography from the left ventricle side was 4.7 ± 0.25 mm, and from the right ventricle side was 3.4 ± 1.1 mm. All were of a perimembranous type except three, which were muscular. All defects were closed with the Amplatzer Duct Occluder II (ADO II) or the ADO II-additional size. The mean fluoroscopy duration and total radiation dose were 22.6 ± 18.7 min and 1674 ± 851 cGy/min, respectively. No aortic regurgitation associated with device closure was seen in any of the patients. Complete atrioventricular block occurred in one patient 6 months after the procedure, and was treated with a permanent pacemaker. VSD closure is challenging, regardless of whether a surgical or percutaneous procedure is used. The risks are higher for children younger than 1 year with low body weight. Percutaneous closure, which carries similar risks but is less invasive than surgery, may be the preferred alternative in early infancy.
To our knowledge, our study includes the largest series of paediatric patients whose ventricular septal defect was closed using Amplatzer Duct Occluder-II percutaneously. When the complications during the 66-month follow-up period are taken into consideration, we can state that Amplatzer Duct Occluder-II is a safe and effective device, even in infants aged <1 year.
It was shown that hypertension incidence as demonstrated by ambulatory blood pressure monitorization and risk for cardiovascular diseases as indicated by CIM thickness and Pulse wave velocity were higher than those in healthy population even after CoA is corrected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.