In this work, trace metals such as Hg, Pb, As, Cd, Cu, Fe, Mn and Zn in underground water samples obtained from three wells, an ash-pond and drinking water located near the Yatagan Thermal Power Plant were measured. As, Hg, Cu and Zn contents of the underground water were lower than those reported in the EEC (European Economic Community) and WHO (World Health Organization) guidelines. In contrast, the levels of Fe, Pb, Cd and Mn in some groundwater samples were higher than EEC and WHO guideline values. The trace metal concentrations in coal ash-pond water were observed to be lower than water quality standards with the exception of Pb. The obtained results indicated that the trace metal concentration in the sampled drinking water site did not exceed WHO limits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.