Understanding the rate of mortality associated with PEG in this patient population and identifying factors that increase and decrease the risk of death will improve patient selection for those most likely to benefit from this procedure.
This study (NCT02428413) evaluated waste anesthetic gas (WAG) in the postanesthesia care unit (PACU) and assessed the utility of the ISO-Gard V R mask in reducing nursing exposure to WAG. We hypothesized that WAG levels in the patient's breathing zone upon recovery would exceed the recommended levels, leading to increased exposure of the PACU nurses, with use of the ISO-Gard mask limiting this exposure. A total of 125 adult patients were recruited to participate. Patients were randomized to receive the standard oxygen delivery mask or the ISO-Gard face mask postoperatively. Continuous particulate concentrations were measured using infrared spectrophotometers placed within the patients' and nurses' 6-inch breathing zone. Maximum WAG measurements were obtained every 30 seconds, and the duration of maximum WAG >2 ppm and its proportion relative to the total collection period were calculated. We observed a statistically significant difference in desflurane duration and proportion of maximum WAG >2 ppm in both patient and PACU nurse breathing zones. Therefore, patients and PACU nurses using routine care were exposed to WAG levels >2 ppm during the 1-hour postoperative period, and the ISO-Gard mask effectively reduced the amount of WAG detected in the immediate 1-hour postoperative recovery phase.
Introduction
Risks of endotracheal tube cuff (ETTC) over inflation must be balanced with the need to achieve a minimum pressure of 20 cm H2O. Methods have been developed to estimate adequate ETTC pressurization but do not provide accurate endotracheal tube cuff pressure (ETCP) measurements. Hence, different sized syringes may play a role in determining ETCP.
Objectives
Determine optimal syringe size for recommended ETCP.
Methods
Two hundred patients were randomized to use of either a 10‐mL syringe (standard syringe) or a 5‐mL syringe (study group) for ETTC inflation. Following the insertion of the endotracheal tube, the ETTC was inflated per the attending anesthesiologist. Within 10 minutes of intubation, ETCP was measured with a hospital‐provided manometer.
Results
The percentage of in range cuff pressures for the 5‐mL group was 10.53% and 6.78% for the 10‐mL group. 84.21% (n = 64) of the study group and 91.53% (n = 54) of the control group had cuff pressures exceeding 30 cmH2O. Although our study did not demonstrate that syringe size was predictive of ideal cuff pressure ranges, the average cuff pressure for the 5‐mL group was 55.8 cm H2O versus 68.8 cm H2O in the 10‐mL group.
Conclusion
Although both 5‐ and 10‐mL syringes resulted in elevated cuff pressures after intubation, 5‐mL syringes resulted in a lower degree of elevation. Use of a 5‐mL syringe should be considered when inflating the endotracheal cuff to possibly reduce patient harm secondary to elevated cuff pressures. Further studies assessing smaller syringe sizes to reduce cuff pressures are warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.