After both AAD and TAA, diabetes mellitus was independently associated with a significantly increased risk of perioperative complications, nonhome discharge, and length of hospital stay during the index hospitalization.
Background: Treatment of failed total ankle arthroplasty (TAA) is challenging. Limited literature is available on options and outcomes of revision arthroplasty despite failure rates ranging from 10% to 23% within 10 years after primary TAA. This study reports the clinical and radiographic outcomes of revision TAA using a fixed-bearing, intramedullary-referencing implant. Methods: A retrospective review was performed of 18 consecutive revision TAA cases between 2008-2015 using an intramedullary-referencing, fixed-bearing, 2-component total ankle system. Demographic and radiographic data were collected preoperatively, immediately postoperatively, and at the most recent follow-up. Functional outcome data were collected immediately postoperatively and at mean follow-up 47.5 months. Results: Eighteen patients underwent revision TAA, with 77.8% (14/18) implant survival. Index revision was performed most commonly for aseptic talar subsidence (55.6%) or implant loosening (tibia, 29.4%; talus, 58.9%). Following revision, 22.2% (4/18) patients required reoperation at a mean 57.3 (39-86) months. Osteolysis of the tibia, talus, and fibula was present preoperatively in 66.7% (12/18), 38.9% (7/18), and 38.9% (7/18) of patients, respectively, with progression of osteolysis in 27.8% (5/18), 11.1% (2/18) and 11.1% (2/18) of patients, respectively. Subsidence of the tibial and talar revision components was observed in 38.9% (7/18) and 55.6% (10/18) of patients, respectively. The median American Orthopaedic Foot & Ankle Society (AOFAS) score was 74.5 (26-100) and Foot Function Index (FFI) score 10.2 (0-50.4). Conclusion: Early results of intramedullary-referencing revision TAA demonstrated good patient-reported outcomes with maintenance of radiographic parameters at mean follow-up of 47.5 months. Aseptic talar subsidence or loosening were the main postoperative causes of reoperation. Revision arthroplasty utilizing an intramedullary-referencing implant was a viable option for the failed TAA. Level of Evidence: Level IV, case series.
Category:
Ankle Arthritis
Introduction/Purpose:
The purpose of this study was to perform a histological comparative analysis of tibiotalar joint samples taken from areas of osteolysis adjacent to total ankle arthroplasties vs control synovial specimens to determine the reaction to and presence of polyethylene (PE) particles.
Methods:
A total of 57 pathology samples were identified in the osteolysis group, while 11 were identified in the control group. For each sample, hematoxylin and eosin, Oil Red O (ORO), and macrophage marker CD163-stained slides were created. Polarized light and ORO stain were used to identify PE particles. The presence of metal particles and giant cell reaction to PE particles were also scored.
Results:
Macrophages, PE particles, metallosis, and foreign body giant cell reaction scores were significantly higher in the osteolysis group compared with the control group. In the osteolysis group, ORO staining was positive in 93% (53/57), birefringent material was present in 96.5% (55/57), and macrophage infiltrates were present in 96.5% (55/57). Foreign body giant cell reaction with giant cells surrounding PE particles was present in 49.1% (28/57) of osteolytic specimens. The presence of foreign body giant cell reaction was associated with significantly higher macrophage, ORO, and polarizable material scores. The average time to surgery for osteolysis from the index ankle replacement was 6.0 (range, 0-15) years for the 57 patients in the osteolysis group.
Conclusion:
This study is the largest ankle arthroplasty histological analysis to show that areas of osteolysis consist of abundant polyethylene wear particles, present both intracellularly and extracellularly. Furthermore, these areas were associated with a CD163+ macrophage infiltrate and frequently a foreign body reaction with giant cells engulfing PE particles. It is likely that implant wear particles play a significant role in osteolysis based on the histopathology.
Based on our clinical experience with postoperative wound care after TAA, use of a compression wrap protocol was safe and effective at reducing wound-related complications, and well tolerated by patients. Further prospective, randomized clinical trials are warranted to evaluate the utility and cost-effectiveness of a compression wrap protocol after TAA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.