BackgroundUse of magnesium for resorbable metal implants is a new concept in orthopaedic and dental medicine. The majority of studies on magnesium’s biocompatibility in vitro have assessed the short-term effect of magnesium extract on cells. The aim of this study was to evaluate the influence of direct exposure to magnesium alloys on the bioactivity of primary human reaming debris-derived (HRD) cells.Materials and methodsPure Mg, Mg2Ag, WE43 and Mg10Gd were tested for biocompatibility. The study consisted of assessment of cell viability by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) test, evaluation of alkaline phosphatase (ALP) content, and study of cell morphology under light microscopy, scanning electron microscopy (SEM) and transmission electron microscopy (TEM), along with determination of calcification and pH changes induced by magnesium.ResultsThe number of viable cells in the presence of Mg2Ag was high over the entire observation period. Inhibition of ALP content in osteogenic differentiating HRD was caused by pure Mg at day 14 and 28. All other magnesium alloys did not affect the ALP content. Exposure of HRD to magnesium increased the amount of lysosomes and endocytotic vesicles. Cellular attachment was generally the best for those crystals that formed on the surface of all materials. A decrease was observed in Ca2+ in the medium from day 1 to day 14.ConclusionsIn terms of cell morphology, cell viability and differentiation, cell density and the effect on the surrounding pH, Mg2Ag showed the most promising results. All magnesium materials induced calcification, which is beneficial for orthopaedic and dental applications.
Background: Implant-associated infections are a result of bacterial adhesion to an implant surface and subsequent biofilm formation at the implantation site. This study compares different magnesium materials based on their ability to resist bacterial adhesion as well as further biofilm formation. Material and Methods: The surfaces of four magnesium-based materials (Mg2Ag, Mg10Gd, WE43 and 99.99% pure Mg) were characterized using atomic force microscope. In addition, the samples were tested for their ability to resist biofilm formation. Planktonic bacteria of either S. epidermidis or E. faecalis were allowed to adhere to the magnesium surfaces for two hour followed by rinsing and, for S. epidermidis, further incubation of 24, 72 and 168 h was carried out. Results: E. faecalis had a significantly stronger adhesion to all magnesium surfaces compared to S. epidermidis (p = 0.001). Biofilm growth of S. epidermidis was different on various magnesium materials: the amount of bacteria increased up to 72 h but interestingly a significant decrease was seen at 168 h on Mg2Ag and WE43 surfaces. For pure Mg and Mg10Gd the biofilm formation reached plateau at 72 h. Surface characteristics of resorbable magnesium materials were changing over time, and the surface was generally less rough at 168 h compared to earlier time points. No correlation was found between the surface topology and the amount of adherent bacteria. Conclusion: In early stages of biofilm adhesion, no differences between magnesium materials were observed. However, after 72 h Mg2Ag and WE43 had the best ability to suppress S. epidermidis' biofilm formation. Also, bacterial adhesion to magnesium materials was not dependent on samples' surface topology.
Pure Mg and W4 were shown to be the most promising materials in this study in respect to the bone response to the implant material. They could be used for screws and plates in bone augmentation procedures.
Introduction: Magnesium has attracted much attention for its potential use in trauma and orthopedics fields due to its mechanical properties, biocompatibility, biodegradability and the possible ability to stimulate bone formation. It is desirable for magnesium-based alloys to have a low toxicity rate so the fractured bone heals before the implant resorbs. Materials and methods:Corrosion properties of Mg2Ag, Mg10Gd, WE43 and 99.99% pure Mg were studied under physiological conditions. The samples were placed in DMEM containing 10% fetal bovine serum (FBS) and corrosion was studied after immersion and by gas evolution tests. The corrosion rate (CR), osmolality, pH and Ca2¬+ concentrations, as well as surface changes in the form of average surface roughness (Sa), developed surface area ratio (Sdr) and summit density (Sds), were determined.Results: WE43 showed the highest CR of all the materials tested-1.057 mm/year, which is almost twice as high as in the other samples. The lowest mean CR was in the Mg2Ag group. All alloys made pH more alkaline and decreased the concentration of free Ca2¬+ in the solution. Osmolality decreased in all samples after day 7. Pure Mg had the most constant Sa and Sdr while WE43 had the most stable Sds of all materials over the observation period. Conclusion:The surface of alloys changed as the implants corroded: the summits became lower with time, while the pitting corrosion progressed. Mg2Ag was the most promising of all the studied materials with regard to toxicity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.