Aim. To present the experience and assess the complications of permanent pacing in children with bradyarrhythmias based on long-term follow-up.Methods. Data of 145 children with structurally normal heart with implanted pacemakers at the age from 1 month to 18 years were retrospectively assessed. The follow-up was from 1999 to 2020 years. Epicardial pacemaker was implanted in 71 children, endocardial - in 74. The mean age of the primary implantation was 8.67±5.2 years.Results. The following complications were disclosed: hemodynamic complications (heart chamber enlargement in dynamics and/or development of dyssynchrony, the appearance and increase in the regurgitation degree on the atrioventricular valves), bacterial endocarditis, hemopericardium, subclavian vein occlusion, pericarditis, infection of the pacemaker and its pocket, leads dislocation and fracture. With epicardial pacing various complications were detected in 24 (33.8%) examined patients, with endocardial - in 37 (50%). Hemodynamic complications with epicardial permanent pacing are associated with intraventricular dyssynchrony due to implantation of a ventricular lead on the lateral wall or the right ventricular outflow tract. Hemodynamic complications were not recorded in patients that performed the implantation of an epicardial lead at the left ventricular (LV) apex.Conclusion. Children with pacemakers require careful follow-up. The most rational is the use of a primary epicardial pacemaker system with lead implantation on the apex of the LV. Such approach allows the veins to be preserved for endocardial stimulation at an older age, and to prevent hemodynamic complications. Neither epicardial nor endocardial pacemaker implantation guarantee the absence of complications. However, compliance with the above conditions will allow achieving high efficiency and safety of cardiac stimulation in children.
Aim: To evaluate the electrical activity of the myocardium and the radiofrequency (RF) application zone resulting from radiofrequency ablation (RFA) performed at an early age.Material and Methods. A prospective follow-up study included three patients who underwent intracardiac electrophysiological study (EPS) and effective RFA of the tachycardia for the first time at an early age. A reintervention was required in one case 12 years after the procedure and in two cases six years after it due to recurrent and new-onset arrhythmias. During the reintervention, electroanatomical mapping was performed to assess the potential damaging effect of radiofrequency exposure in the area of the first ablation.Results. The intracardiac EPS and amplitude bipolar CARTO-reconstruction of primary ablation area were performed during repeated RFA procedure. The study showed that neither zones with a decrease in the amplitude of electrical signal from the myocardium nor silent electrical zones were present ruling out the cicatricial-sclerotic changes in the myocardium in children in the long-term period after RF exposure.Conclusion. The study showed that no increase in the coagulation necrosis zone in the area of primary ablation occurred during the growth of child when the sparing energy and temperature parameters of RFA and the limited number of RF applications were used. Further research in this area is required.
Первичные кардиомиопатии в детском возрасте представляют собой редкое, но серьезное заболевание, которое является частой причиной сердечной недостаточности и наиболее частой причиной трансплантации сердца у детей старше 1 года. За последние десятилетия диагностика кардиомиопатии продвинулась от традиционных клинических подходов к новым генетическим и визуализационным методам. В статье представлен обзор литературных данных о современной классификации первичных педиатрических кардиомиопатий, особенностях клинического течения и визуализации, которая является неотъемлемой частью диагностики на основе первичного морфофункционального фенотипа.
Heart rhythm disorders (HRDs) are one of the most complex and urgent problems in both adult and pediatric cardiology. One of the important points of research in the field of arrhythmology is the study of the mechanisms of HRD formation. The mechanisms that trigger arrhythmias in children have their own peculiarity associated with the age-related aspects of the formation of both the cardiovascular system and the systems responsible for its regulation, primarily the autonomic nervous system (ANS). The article presents current literature data on the contribution of the ANS to the formation of arrhythmias and the information content of its markers depending on age.
Background. Currently pacing is the only treatment option for life-threatening bradyarrhythmias. Considering the specific factors of pediatric patients, specialists in this field should be highly professional.Aim: To present the experience and retrospective analysis of complications of permanent pacing in children and adolescents from Tomsk National Research Medical Center.Material and Methods. Complications of permanent pacing in children with structurally normal heart and children with congenital heart defects were analyzed. The follow-up was from 1999 to 2021 years. 256 patients aged from 1 month to 18 years participated in the study. Epicardial pacemaker was implanted in 173 children, endocardial – in 83 patients. Average time from primary implantation to complications was 2.1 ± 2.7 years.Results. Hemodynamic complications are the most common among patients with epicardial and endocardial permanent pacing. Hemodynamic complications with epicardial permanent pacing are associated with intraventricular dissynchrony due to stimulation in the area of the lateral wall or the right ventricular outflow tract. In patients with endocardial permanent pacing hemodynamic complications are associated with the development of pacemaker-induced cardiomyopathy due to permanent pacing of the right ventricle apex and tricuspid regurgitation. Complications such as bacterial endocarditis, infection of the pacemaker and its bed, hemopericardium, subclavian vein occlusion, pericarditis, peacemaker dislocation and lead fracture were less common. Two cases of cardiac strangulation were detected.Conclusion. Neither epicardial nor endocardial pacemaker implantation guarantee the absence of complications. Implantation of the electrode on the apex of the left ventricle (epicardial pacemaker system), in the area of the His bundle (endocardial pacemaker system), prevents the development of hemodynamic complications. The most rational is the use of a primary epicardial pacemaker system. Such approach allows the veins to be preserved for endocardial stimulation at an older age.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.