A novel electrochemical sensor was fabricated by simply screen printing reduced graphene oxide (rGO) paste on F-doped tin oxide (FTO) (rGO-SP-FTO) followed by sintering at 450 • C in Argon and employed for detecting dopamine (DA) and uric acid (UA) simultaneously. The rGO film was characterized by using Raman spectroscopy, field emission scanning electron microscope (FE-SEM), and Fourier transform infrared spectroscopy (FTIR). The surface sensing features of rGO-SP-FTO were studied with electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The rGO-SP-FTO electrode exhibited foremost sensitivity in simultaneous detection of DA and UA without any interference from ascorbic acid (AA). The rGO-SP-FTO electrode showed a good linear response in the range of 0.5-50.0 μM and 5.0-300 μM with detection limits (S/N = 3) of 0.07 μM and 0.39 μM for DA and UA, respectively. The interactions between screen printed rGO with FTO electrode and their influence on how rGO-SP-FTO electrode interacted with UA, DA, and AA were analyzed from experimental observations. The rGO-SP-FTO electrode was able to detect DA in dopamine hydrochloride injection (DAI) and UA in urine sample effectively. Moreover, the designed electrochemical sensor exhibited excellent stability and reproducibility.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.