Early identification and isolation of tuberculosis patients is of utmost importance to minimize the risk of further epidemic spread of the disease. The traditional concentrated acid-fast smears are not very reliable tools for the presumptive diagnosis of tuberculosis. Acid-fast bacillus (AFB) smears from 120 patient specimens and 80 simulated AFB samples were processed according to standard laboratory procedures and by cytocentrifugation (Cyto-Tek, Ames Division, Miles Laboratories, Inc., Elkhart, Ind.). Prior to dispensing of samples into the Cyto-Tek chambers, specimens were liquefied and decontaminated by mixture with an equal volume of 5% sodium hypochlorite (household bleach). Culture and smear results were correlated. Of 120 patient specimens, 43 were culture and smear negative by both methods. Ten specimens were overgrown with mold and bacteria, but 2 of them had positive AFB smears by cytocentrifugation only. There were 67 positive AFB cultures, with 67 positive cytocentrifuge smears and 34 positive smears by the conventional technique. Of the 80 simulated positive AFB samples, all grew mycobacteria on culture. Smears from the i0to 103-CFU/ml specimens were positive by both methods. The simulated samples with 102 CFU/ml yielded smears positive only by
The Delves micro-scale technique for blood lead analysis is an accurate method for screening capillary blood specimens, obtained by fingerstick, for lead intoxication. Results are affected by the age of cup, loop, and hollow-cathode tube and by the spatial relationship between optical tube and cup. Because the glass in many commercially available capillary tubes (used in specimen collection) contains lead and cannot be decontaminated, a lead-free glass tube must be used. A solution of citric acid in ethanol (20 g/liter) effectively cleanses the puncture site. A double-blind study of 207 specimens gave a mean value of 276.6 ± 105.8 µg/liter (1 SD) for the micro-scale method vs. 273.2 ± 99.0 for a macro-scale method. The mean coefficent of variation for the micro-scale method was 5.75% ± 1.9 (SD). We conclude that values of 480 µg/liter or below are not "toxic" (i.e., are significantly less than 600 µg/liter, the value at which therapy is begun). The method is shown to be satisfactory as a screening procedure and for confirming lead analyses done by other methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.