BackgroundThe implantation depth (ID) is a critical condition for optimal hemodynamic and clinical outcomes in transcatheter aortic valve replacement (TAVR). The recently recommended cusp-overlap technique (COT) offers optimized fluoroscopic projections facilitating a precise ID. This single-center observational study aimed to investigate short-term clinical performance, safety, and efficacy outcomes in patients undergoing TAVR with self-expandable prostheses and application of COT in a real-world setting.Materials and methodsFrom September 2020 to April 2021, a total of 170 patients underwent TAVR with self-expandable devices and the application of COT, while 589 patients were treated from January 2016 to August 2020 with a conventional three-cusp coplanar view approach. The final ID and 30-day outcomes were compared after 1:1 propensity score matching, resulting in 150 patients in both cohorts.ResultsThe mean ID was significantly reduced in the COT cohort (−4.2 ± 2.7 vs. −4.9 ± 2.3 mm; p = 0.007) with an improvement of ID symmetry of less than 2 mm difference below the annular plane (47.3 vs. 57.3%; p = 0.083). The rate of new permanent pacemaker implantation (PPI) following TAVR was effectively reduced (8.0 vs. 16.8%; p = 0.028). While the fluoroscopy time decreased (18.4 ± 7.6 vs. 19.8 ± 7.6 min; p = 0.023), the dose area product increased in the COT group (4951 ± 3662 vs. 3875 ± 2775 Gy × cm2; p = 0.005). Patients implanted with COT had a shorter length of in-hospital stay (8.4 ± 4.0 vs. 10.3 ± 6.7 days; p = 0.007).ConclusionTranscatheter aortic valve replacement using the cusp-overlap deployment technique is associated with an optimized implantation depth, leading to fewer permanent conduction disturbances. However, our in-depth analysis showed for the first time an increase of radiation dose due to extreme angulations of the gantry to obtain the cusp-overlap view.
Due to shortages of medical resources during the Coronavirus Disease 2019 (COVID-19) pandemic, an allocation algorithm for Transcatheter Aortic Valve Replacement (TAVR) was established. We investigated the impact on patient selection and procedural results. In total, 456 TAVR patients before (pre-COVID-19 group) and 456 TAVR patients after (COVID-19 group) the implementation of our allocation algorithm were compared. Concerning patient characteristics, the COVID-19 group revealed a higher rate of cardiac decompensations/cardiogenic shocks (10.5% vs. 1.3%; p < 0.001), severe angina pectoris (Canadian Cardiovascular Society (CCS) II, III and IV: 18.7% vs. 11.8%; p = 0.004), troponin elevation (>14 ng/L: 84.9% vs. 77%; p = 0.003) and reduced left ventricular ejection fraction (LVEF) (<45%: 18.9% vs. 12%; p = 0.006). Referring to procedural characteristics, more predilatations (46.3% vs. 35.1%; p = 0.001) and a longer procedural time (80.2 min (+/−29.4) vs. 66.9 min (+/−17.5); p < 0.001) were observed. The success rate was evenly high; no differences in safety parameters were reported. Examining the utilization of hospital resources, the COVID-19 group showed a shorter in-hospital stay (8.4 days (+/−5.9) vs. 9.5 days (+/−9.33); p = 0.041) and fewer TAVR patients were treated per month (39 (+/−4.55) vs. 46.11 (+/−7.57); p = 0.03). Our allocation algorithm supported prioritization of sicker patients with similar efficient and safe TAVR procedures. In-hospital stay could be shortened.
Exact and reliable measurements of anatomical dimensions in pre-procedural multi-slice computed tomography (MSCT) scans are crucial for optimal valve sizing and clinical results of transcatheter aortic valve replacement (TAVR). This study aimed to investigate interrater reliability between routinely used workflows for pre-procedural analysis. MSCT scans of 329 patients scheduled for TAVR were analyzed using both a 3mensio and SECTRA IDS7 platform. The results were retrospectively compared using the intraclass correlation coefficient, revealing excellent correlation in the analysis of simple diameters and poor correlation in the assessment of more complex structures with impact on calculated valve size.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.