Objectives: Central venous access devices, including peripherally inserted central catheters and central venous catheters, are often needed in critically ill patients, but also are associated with complications, including central-line associated bloodstream infections and venous thromboembolism. We compared different central venous access device types and these complications in the PICU. Design: Multicenter, cohort study. Setting: One hundred forty-eight participating Virtual PICU Systems, LLC, hospital PICU sites. Patients: Pediatric patients with central venous access placed from January 1, 2010, to December 31, 2015. Interventions: None. Measurements and Main Results: Patient and central venous access device variables postulated to be associated with central-line associated bloodstream infection and venous thromboembolism were included. Data were analyzed using Pearson chi-square test or Fisher exact test for categorical variables, Mann-Whitney U test for continuous variables, and logistic regression and classification trees for multivariable analysis that examined significant predictors of venous thromboembolism or central-line associated bloodstream infection. Analysis included 74,196 first lines including 4,493 peripherally inserted central catheters and 66,194 central venous catheters. An increased rate of venous thromboembolism (peripherally inserted central catheter: 0.93%, central venous catheter: 0.52%; p = 0.001) (peripherally inserted central catheter: 8.65/1,000 line days, central venous catheter: 6.29/1,000 line days) and central-line associated bloodstream infection (peripherally inserted central catheter: 0.73%, central venous catheter: 0.24%; p = 0.001) (peripherally inserted central catheter: 10.82/1,000 line days, central venous catheter: 4.97/1,000 line days) occurred in peripherally inserted central catheters. In multivariable analysis, central venous catheters had decreased association with central-line associated bloodstream infection (odds ratio, 0.505; 95% CI, 0.336–0.759; p = 0.001) and venous thromboembolism (odds ratio, 0.569; 95% CI, 0.330–0.982; p = 0.043) compared with peripherally inserted central catheters. Conclusions: Peripherally inserted central catheters are associated with higher rates of central-line associated bloodstream infection and venous thromboembolism than central venous catheters in children admitted to the PICU.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.