Impaired response to COVID-19 vaccination is of particular concern in immunosuppressed patients. To determine the best vaccination strategy for this vulnerable group we performed a single center, 1:1 randomized blinded clinical trial. Patients who failed to seroconvert upon two mRNA vaccinations (BNT162b2 or mRNA-1273) are randomized to receive either a third dose of the same mRNA or the vector vaccine ChAdOx1 nCoV-19. Primary endpoint is the difference in SARS-CoV-2 spike antibody seroconversion rate between vector and mRNA vaccinated patients four weeks after the third dose. Secondary outcomes include cellular immune responses. Seroconversion rates at week four are significantly higher in the mRNA (homologous vaccination, 15/24, 63%) as compared to the vector vaccine group (heterologous vaccination, 4/22, 18%). SARS-CoV-2-specific T-cell responses are reduced but could be increased after a third dose of either vector or mRNA vaccine. In a multivariable logistic regression analysis, patient age and vaccine type are associated with seroconversion. No serious adverse event is attributed to COVID-19 booster vaccination. Efficacy and safety data underline the importance of a booster vaccination and support the use of a homologous mRNA booster vaccination in immunosuppressed patients.Trial registration: EudraCT No.: 2021-002693-10.
Purpose: Dry eye disease (DED) is a highly prevalent ocular condition with a significant burden on affected patients. Regardless of the underlying etiology, DED is associated with increased ocular surface inflammation. We investigated the safety and efficacy of a shortterm treatment with topical low dose hydrocortisone in patients with chronic DED and ocular surface inflammation. Methods: A total of 60 patients (mean age 51 ± 14 years) with chronic DED and conjunctival hyperemia greater than grade 2 on the Efron scale were included. Patients were randomized to receive either preservative-free hydrocortisone 0.335% (Softacort, Laboratories Thea, France) for 12 days four times daily followed by 2 days twice daily instillation (intense treatment group) or 8 days three times daily followed by 3 days twice daily treatment (standard treatment group). Ocular redness was assessed at baseline, day 14, and day 28. Measurement of intraocular pressure (IOP) and clinical tests to assess signs and symptoms of DED were performed. Results: Conjunctival hyperemia and Ocular Surface Disease Index (OSDI) significantly decreased in both treatment groups (p \ 0.001 each) after hydrocortisone treatment. A significant increase in tear film thickness was seen 4 weeks after treatment start (p = 0.03 and p = 0.04, respectively). IOP did not change in either of the two treatment groups (p = 0.45). Conclusion: Treatment with low dose hydrocortisone 0.335% reduced ocular inflammation and decreased OSDI score. No change in IOP was observed in either of the two treatment schedules. Because of its good safety profile, low dose The original version of this article was revised due to retrospective open access.
Citation: Puchner S, Schmidl D, Ginner L, et al. Changes in retinal blood flow in response to an experimental increase in IOP in healthy participants as assessed with Doppler optical coherence tomography. Invest Ophthalmol Vis Sci. 2020;61(2):33. https://doi.org/10.1167/iovs.61.2.33 PURPOSE.Blood flow autoregulation is an intrinsic mechanism of the healthy retinal vasculature to keep blood flow constant when ocular perfusion pressure (OPP) is changed. In the present study, we set out to investigate retinal blood flow in response to an experimental decrease in OPP in healthy participants using Doppler optical coherence tomography. METHODS.Fifteen healthy participants aged between 22 and 31 years (mean, 27 ± 3 years) were included in the present open study. IOP was increased stepwise via the suction cup method to induce a decrease in OPP. Retinal blood flow in arteries and veins was assessed using a custom-built Doppler optical coherence tomography system and pressure-flow relationships were calculated to assess autoregulation. RESULTS.Suction cup application induced a pronounced increase in IOP with a maximum value of 50.5 ± 8.0 mm Hg at the highest level of suction. Pressure-flow relationships revealed that blood flow was autoregulated until the OPP was decreased by approximately 21 mm Hg and started to decrease significantly when the OPP was reduced by 30 mm Hg. Retinal blood flow at the last suction period decreased at a maximum of -57.0 ± 22.3% and 65.2 ± 15.4% in retinal arteries and retinal veins, respectively. These changes in retinal blood flow were less pronounced than the decrease in OPP (-75.2 ± 19.2%), indicating retinal autoregulation. CONCLUSIONS.The results of the present study confirm that retinal blood flow is autoregulated in response to changes in the OPP. Doppler optical coherence tomography has the potential to become a clinical tool for the investigation of retinal blood flow autoregulation in the future, because of its ability to assess the blood velocities and diameter of the retinal vessels parallel and therefore also their blood flow in absolute values. (Clinicaltrials.gov number NCT03398616)
To investigate the repeatability and reproducibility of total retinal blood flow measurements using a custom-built dual-beam bidirectional Doppler optical coherence tomography (OCT) system in healthy subjects. Methods: Repeatability and reproducibility were analyzed in 10 and 34 healthy subjects, respectively. For repeatability, measurements were taken twice within 30 minutes, for reproducibility, twice within two to five weeks. Two analysis approaches were compared for calculation of absolute blood velocities: a previously published approach resulting in values for total arterial (Q A,abs) and total venous blood flow (Q V,abs) and a novel approach taking into account that there is a fixed relation between the phase shift in the two OCT channels (Q A,new, Q V,new). Repeatability and reproducibility were quantified using intraclass correlation coefficients (ICCs). Results: For Q A,abs and Q V,abs , ICC values between 0.78 and 0.84 were obtained. Q A,new and Q V,new values revealed better repeatability and reproducibility as compared to the convential appoach. Repeatability ICCs for Q A,new and Q V,new were between 0.91 and 0.93, and reproducibility ICCs were between 0.87 and 0.91 indicating excellent reproducibility. Good agreement was observed between total retinal blood flow values as measured from retinal arteries and retinal veins. Conclusions: Measurement of total retinal blood flow using dual-beam Doppler OCT shows excellent reproducibility, which can further be improved by using a novel algorithm for calculating blood velocities in retinal vessels. Translational Relevance: Our data indicate that dual-beam Doppler OCT can be used for longitudinal studies. Hence, quantitative retinal blood flow may be established as a biomarker for progression vascular eye diseases.
To investigate the response of the superficial and deep capillary plexuses to hyperoxia and hypoxia using optical coherence tomography angiography (OCT-A) and retinal vessel analyzer.Methods: Twenty-four healthy volunteers participated in this randomized, double-masked, crossover study. For each subject, two study days were scheduled: on one study day, hyperoxia was induced by breathing 100% oxygen whereas on the other study day, hypoxia was induced by breathing a mixture of 88% nitrogen and 12% oxygen. Perfusiondensity wascalculated in the superficial vascular plexus (SVP) and the deep capillary plexus (DCP), using OCT-A before (normal breathing) and during breathing of the gas mixtures. Retinal vessel calibres in major retinal vessels were measured using a dynamic vessel analyzer.Results: During 100% oxygen breathing, a significant decrease in DCP perfusion density from 41.7 AE 2.4 a.u to 35.6 AE 3.1 a.u. (p < 0.001) was observed, which was accompanied by a significant decrease in vessel diameters in majorretinal arteries and veins(p < 0.001 each). No significant change in perfusion density in the SVP occurred (p = 0.33). In contrast, during hypoxia, perfusion density in the SVP significantly increased from 34.4 AE 3.0a.u.to 37.1 AE 2.2 a.u. (p < 0.001), while it remained stable in the DCP (p = 0.25). A significant increase in retinal vessel diameters was found (p < 0.01). Systemic oxygen saturation correlated negatively with perfusion density in the SVP and the DCP and retinal vessel diameters (p < 0.005 each). Conclusion:Our results show that systemic hyperoxia induces a significant decrease in vessel density in the DCP, while hypoxia leads to increased vessel density limited to the SVP. These results indicate that the retinal circulation shows the ability to adapt its blood flow to metabolic changes with high local resolution dependent on the capillary plexus.
Objectives A third COVID-19 vaccination is recommended for immunosuppressed patients. However, data on immunogenicity and safety of a third COVID-19 vaccination in patients with immune-mediated inflammatory diseases (IMIDs) are sparse and therefore addressed within this clinical trial. Methods 60 immunosuppressed patients and 48 healthy controls (HCs) received a third vaccination with an mRNA vaccine. The primary endpoint was defined as the presence of antibody levels against the receptor-binding domain (RBD)>1500 BAU/mL in patients with IMIDs versus HCs. Further endpoints included differences in neutralising antibodies and cellular immune responses after the third vaccination. Reactogenicity was recorded for 7 days, and safety was evaluated until week 4. Results Rate of individuals with anti-RBD antibodies>1500 BAU/mL was not significantly different after the third vaccination between patients with IMIDs and HCs (91% vs 100% p=0.101). Anti-RBD and neutralising antibody levels were significantly lower in patients with IMIDs after the third vaccination than in HCs (p=0.002 and p=0.016, respectively). In contrast, fold increase in antibody levels between week 0 and 4 was higher in patients with IMIDs. Treatment with biological (b) disease-modifying anti-rheumatic drugs (DMARD) or combination of bDMARDs and conventional synthetic DMARDs was associated with reduced antibody levels. Enhanced cellular immune response to wild type and Omicron peptide stimulation was observed after the third vaccination. No serious adverse event was attributed to the third vaccination. ConclusionOur clinical trial data support the immunogenicity and safety of a third COVID-19 vaccination in patients with IMIDs. However, effects of DMARD therapy on immunogenicity should be considered. Trial registration number EudraCT No: 2021-002693-10. HOW THIS STUDY MIGHT AFFECT RESEARCH, PRACTICE OR POLICY ⇒ Patients with IMIDs should receive a third vaccination.
Background/aims Concerning healthcare approaches, a paradigm change from reactive medicine to predictive approaches, targeted prevention, and personalisation of medical services is highly desirable. This raises demand for biomarker signatures that support the prediction and diagnosis of diseases, as well as monitoring strategies regarding therapeutic efficacy and supporting individualised treatments. New methodological developments should preferably rely on non-invasively sampled biofluids like sweat and tears in order to provide optimal compliance, reduce costs, and ensure availability of the biomaterial. Here, we have thus investigated the metabolic composition of human tears in comparison to finger sweat in order to find biofluid-specific marker molecules derived from distinct secretory glands. The comprehensive investigation of numerous biofluids may lead to the identification of novel biomarker signatures. Moreover, tear fluid analysis may not only provide insight into eye pathologies but may also be relevant for the prediction and monitoring of disease progression and/ or treatment of systemic disorders such as type 2 diabetes mellitus. Methods Sweat and tear fluid were sampled from 20 healthy volunteers using filter paper and commercially available Schirmer strips, respectively. Finger sweat analysis has already been successfully established in our laboratory. In this study, we set up and evaluated methods for tear fluid extraction and analysis using high-resolution mass spectrometry hyphenated with liquid chromatography, using optimised gradients each for metabolites and eicosanoids. Sweat and tears were systematically compared using statistical analysis. As second approach, we performed a clinical pilot study with 8 diabetic patients and compared them to 19 healthy subjects. Results Tear fluid was found to be a rich source for metabolic phenotyping. Remarkably, several molecules previously identified by us in sweat were found significantly enriched in tear fluid, including creatine or taurine. Furthermore, other metabolites such as kahweol and various eicosanoids were exclusively detectable in tears, demonstrating the orthogonal power for biofluid analysis in order to gain information on individual health states. The clinical pilot study revealed that many endogenous metabolites that have previously been linked to type 2 diabetes such as carnitine, tyrosine, uric acid, and valine were indeed found significantly up-regulated in tears of diabetic patients. Nicotinic acid and taurine were elevated in the diabetic cohort as well and may represent new biomarkers for diabetes specifically identified in tear fluid. Additionally, systemic medications, like metformin, bisoprolol, and gabapentin, were readily detectable in tears of patients. Conclusions The high number of identified marker molecules found in tear fluid apparently supports disease development prediction, developing preventive approaches as well as tailoring individual patients’ treatments and monitoring treatment efficacy. Tear fluid analysis may also support pharmacokinetic studies and patient compliance control.
It has been hypothesized that besides its intraocular pressure (IOP) lowering potential, tetrahydrocannabinol (THC) may also improve ocular hemodynamics. The aim of the present study was to investigate whether single oral administration of dronabinol, a synthetic THC, alters optic nerve head blood flow (ONHBF) and its regulation in healthy subjects. The study was carried out in a randomized, placebo‐controlled, double‐masked, two‐way crossover design in 24 healthy subjects. For each study participant, 2 study days were scheduled, on which they either received capsules containing 5 mg dronabinol or placebo. ONHBF was measured with laser Doppler flowmetry at rest and while the study participants performed isometric exercise for 6 minutes to increase mean arterial blood pressure (MAP). This was repeated 1 hour after drug intake. Ocular perfusion pressure (OPP) was calculated as 2/3MAP–IOP. Dronabinol was well tolerated and no cannabinoid‐related psychoactive effects were reported. Neither administration of dronabinol nor placebo had an effect on IOP, MAP, or OPP. In contrast, dronabinol significantly increased ONHBF at rest by 9.5 ± 8.1%, whereas placebo did not show a change in ONHBF (0.3 ± 7.4% vs. baseline, P < 0.001 between study days). Dronabinol did not alter the autoregulatory response of ONHBF to isometric exercise. In conclusion, the present data indicate that low‐dose dronabinol increases ONHBF in healthy subjects without affecting IOP, OPP, or inducing psychoactive side effects. In addition, dronabinol does not alter the autoregulatory response of ONHBF to an experimental increase in OPP. Further studies are needed to investigate whether this effect can also be observed in patients with glaucoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.