Background:Carotid artery calcification may be related to cerebrovascular accident, which may result in death or physical and mental disabilities in survivors.Objectives:Our purpose is to study the association of carotid artery calcification (CAC) on dental panoramic radiographs and two risk factors of cerebrovascular accident (CVA) including hypertension and myocardial infarction (MI).Patients and Methods:Panoramic images of 200 patients that were all women above 50 years of age (a population suffering from vascular diseases) were investigated. All panoramic images were provided under similar conditions in terms of the type of panoramic radiograph equipment, type of applied films and the automatic film processor. Then, the patients answered questions about MI history and taking antihypertensive drugs. We also measured the blood pressure of patients in two separate surveys. Data analysis was performed by SPSS statistical program. We used Exact Fisher test and Chi-Square test at a significant level of less than 0.05 to study the effect of these variables on the occurrence of carotid artery calcification.Results:Among 200 studied samples, 22 of the patients (11%) had carotid artery calcification on the dental panoramic radiograph. In total, 52 patients (26%) had hypertension and four people (2%) had a history of MI. Eleven individuals among patients suffering from hypertension (21.2%) and three individuals among patients with a history of MI (75%) demonstrated CAC on dental panoramic images .Conclusions:The relationship between CAC found on dental panoramic radiographs and two CVA risk factors--hypertension and MI-- was significant. Therefore, it seems that detection of CAC on panoramic images of dental patients must be considered by dentists.
BackgroundMarketing new radiography devices necessitates documenting their absorbed X-ray doses. Since the current literature lacks studies on new devices, we assessed the doses of two new devices that had not previously been assessed.ObjectivesThe new devices were compared to the Promax three dimensional (3D) scanner at two fields of view (FOV) in nine critical head and neck tissues and organs.Materials and MethodsSeventeen thermoluminescence dosimeters positioned in an average-sized male RANDO phantom were used to determine the dosimetry of the three cone beam computerized tomography devices (NewTom VGi, NewTom 5G, and Promax 3D) at two field of views (FOVs), one small and one large. The exposure by each device per FOV was performed five times (30 exposures). The absorbed and effective doses were calculated for the thyroid, parotid, submandibular gland, sublingual gland, calvarium, cervical vertebra, trunk of the mandible, and mandibular ramus. The doses pertaining to the different devices, the FOVs, and the tissues were compared using the Kruskal-Wallis, Mann-Whitney U, and Wilcoxon tests.ResultsThe average absorbed doses, respectively, for the large and small FOVs were 17.19 and 28.89 mGy in the Promax 3D, 19.25 and 35.46 mGy in the NewTom VGi, and 18.85 and 30.63 mGy in the NewTom 5G. The absorbed doses related to the FOVs were not significantly different (P value = 0.1930). However, the effective doses were significantly greater at the smaller FOVs / higher resolutions (P = 0.0039). The doses of the three devices were not significantly different (P = 0.8944). The difference among the nine organs/tissues was significant (Kruskal-Wallis P=0.0000).ConclusionThe absorbed doses pertaining to the devices and the FOVs were not significantly different, although the organs/tissues absorbed considerably different doses.
Background and aims. The aim of this study was to evaluate the intra- and inter-examiner reliability and reproducibility of linear measurements on cone-beam computed tomography (CBCT) images made by calibrated radiologists and periodontists. Materials and methods. The alveolar ridge dimensions were measured on selected CBCT images by two calibrated radiologists and two periodontists. Intra- and inter-examiner reliability was evaluated by intra-rater and intra-class correlation coefficients (ICCs). Results. Intra- and inter-examiners ICCs obtained with the different methods showed almost perfect matches. The results demonstrated high examiner reproducibility for linear parameters of alveolar ridges on CBCT images in presurgical implant site assessments. Conclusion. The alveolar ridge dimensions provided by the radiologists might be useful for the periodontists. The measurements with small differences were related to the experience and skills of the examiner, inclination measurement, selection of the exact level of the alveolar crest and the ability to detect the exact anatomic borders on CBCT images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.