IntroductionTotal hip replacement is one of the most commonly performed major orthopaedic operations. Goal-directed therapy (GDT) using haemodynamic monitoring has previously demonstrated outcome benefits in high-risk surgical patients under general anaesthesia. GDT has never been formally assessed during regional anaesthesia.MethodsPatients undergoing total hip replacement while under regional anaesthesia were randomised to either the control group (CTRL) or the protocol group (GDT). Patients in the GDT group, in addition to standard monitoring, were connected to the FloTrac sensor/Vigileo monitor haemodynamic monitoring system, and a GDT protocol was used to maximise the stroke volume and target the oxygen delivery index to > 600 mL/minute/m2.ResultsPatients randomised to the GDT group were given a greater volume of intravenous fluids during the intraoperative period (means ± standard deviation (SD): 6,032 ± 1,388 mL vs. 2,635 ± 346 mL; P < 0.0001), and more of the GDT patients received dobutamine (0 of 20 CTRL patients vs. 11 of 20 GDT patients; P < 0.0003). The GDT patients also received more blood transfused during the intraoperative period (means ± SD: 595 ± 316 mL vs. 0 ± 0 mL; P < 0.0001), although the CTRL group received greater volumes of blood replacement postoperatively (CTRL patients 658 ± 68 mL vs. GDT patients 198 ± 292 mL; P < 0.001). Overall blood consumption (intraoperatively and postoperatively) was not different between the two groups. There were an increased number of complications in the CTRL group (20 of 20 CTRL patients (100%) vs. 16 of 20 GDT patients (80%); P = 0.05). These outcomes were predominantly due to a difference in minor complications (20 of 20 CTRL patients (100%) vs. 15 of 20 GDT patients (75%); P = 0.047).ConclusionsGDT applied during regional anaesthesia in patients undergoing elective total hip replacement changes intraoperative fluid management and may improve patient outcomes by decreasing postoperative complications. Larger trials are required to confirm our findings.Trial registrationSRCTN11616985
Background: One-lung ventilation (OLV) in thoracic anesthesia is required to provide good surgical exposure. OLV is commonly achieved through a double lumen tube (DLT) or a bronchial blocker (BB). Malposition is a relevant issue related to these devices use. No prospective studies with adequately large sample size have been performed to evaluate the malposition rate of DLTs and BBs. Methods: A total of 2,127 patients requiring OLV during thoracic surgery were enrolled. The aim of this multicenter prospective observational study performed across 26 academic and community hospitals is to evaluate intraoperative malposition rate of DLTs and BBs. We also aim to assess: which device is the most used to achieve OLV, the frequency of bronchoscope (BRO) use, the incidence rate of desaturation during OLV and the role of other factors that can correlate to this event, and incidence of difficult airway. Results: Malposition rate for DLTs was 14%, for BBs 33%. DLTs were used in 95% of patients and BBs in 5%. Mean positioning time was shorter for DLT than BB (156±230 vs. 321±290 s). BRO was used in 54% of patients to check the correct positioning of the DLT. Desaturation occurred in 20% of all cases during OLV achieved through a DLT. Predicting factors of desaturation were dislocation (OR 2.03) and big size of DLT (OR 1.15). BRO use (OR 0.69) and left surgical side (OR 0.41) proved to be protective factors. Difficult
BackgroundThe aim of this study was to evaluate pre- and post-operative brain natriuretic peptide (BNP) levels and compare the power of this test in predicting in-hospital major adverse cardiac events (MACE: atrial fibrillation, flutter, acute heart failure or non-fatal/fatal myocardial infarction) in patients undergoing elective prosthesis orthopedic surgery to that of the Revised Cardiac Risk Index (RCRI) and American Society of Anesthesiology (ASA) class, the most useful scores identified to date.MethodsThe study was an observational study of consecutive patients undergoing elective prosthesis orthopedic surgery. Surgical risk was established using RCRI score and ASA class criteria. Venous blood was sampled before surgery and on postoperative day 1 for the measurement of BNP. The intraoperative data collected included details of the surgery and anesthesia and any MACE experienced up until hospital discharge.ResultsMACE occurred in 14 of the 227 patients treated (6.2%). Age was statistical associated with MACE (p < 0.004). Preoperative BNP levels were higher (p < 0.0007) in patients who experienced MACE than in event-free patients (median values: 92 and 35 pg/mL, respectively). Postoperative BNP levels were also greater (p < 0.0001) in patients sustaining MACE than in event-free patients (median values: 165 and 45 pg/mL, respectively). ROC curve analysis demonstrated that for a cut-off point ≥ 39 pg/mL, the area under the curve for preoperative BNP was equal to 0.77, while a postoperative BNP cut-off point ≥ 69 pg/mL gave an AUC of 0.82.ConclusionsBoth pre- and post-operative BNP concentrations are predictors of MACE in patients undergoing elective prosthesis orthopedic surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.