The growth of microorganisms may be limited by operating conditions which provide an inadequate supply of oxygen. To determine the oxygen-transfer capacities of small-scale bioreactors such as shaking flasks, test tubes, and microtiter plates, a noninvasive easy-to-use optical method based on sulfite oxidation has been developed. The model system of sodium sulfite was first optimized in shaking-flask experiments for this special application. The reaction conditions (pH, buffer, and catalyst concentration) were adjusted to obtain a constant oxygen transfer rate for the whole period of the sulfite oxidation reaction. The sharp decrease of the pH at the end of the oxidation, which is typical for this reaction, is visualized by adding a pH dye and used to measure the length of the reaction period. The oxygen-transfer capacity can then be calculated by the oxygen consumed during the complete stoichiometric transformation of sodium sulfite and the visually determined reaction time. The suitability of this optical measuring method for the determination of oxygen-transfer capacities in small-scale bioreactors was confirmed with an independent physical method applying an oxygen electrode. The correlation factor for the maximum oxygen-transfer capacity between the chemical model system and a culture of Pseudomonas putida CA-3 was determined in shaking flasks. The newly developed optical measuring method was finally used for the determination of oxygen-transfer capacities of different types of transparent small-scale bioreactors.
We present the assets and constraints of using optical parametric oscillators (OPOs) to perform point scanning nonlinear microscopy and spectroscopy with special emphasis on coherent Raman spectroscopy. The different possible configurations starting with one OPO and two OPOs are described in detail and with comments that are intended to be practically useful for the user. Explicit examples on test samples such as nonlinear organic crystal, polystyrene beads, and fresh mouse tissues are given. Special emphasis is given to background-free coherent Raman anti-Stokes scattering (CARS) imaging, including CARS hyperspectral imaging in a fully automated mode with commercial OPOs.
Two-stage multipass-cell compression of a fiber–chirped-pulse amplifier
system to the few-cycle regime is presented. The output delivers a
sub-2-cycle (5.8 fs), 107 W average power, 1.07 mJ pulses at 100 kHz
centered at 1030 nm with excellent spatial beam quality (M2 = 1.1, Strehl ratio S = 0.98), pointing stability (2.3 µrad), and
superior long-term average power stability of 0.1% STD over more than
8 hours. This is combined with a carrier-envelope phase stability of
360 mrad in the frequency range from 10 Hz to 50 kHz, i.e., measured
on a single-shot basis. This unique system will serve as an HR1 laser
for the Extreme Light Infrastructure Attosecond Light Pulse Source
research facility to enable high repetition rate isolated attosecond
pulse generation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.