BackgroundValidation of new affordable CD4 T cell measurement technologies is crucial specifically in resource-poor countries for antiretroviral treatment eligibility and immunologic CD4 monitoring of HIV-infected patients.MethodsThe absolute and percentage CD4 T cell counts of 258 HIV-1-infected blood samples (182 adults and 76 children), living in N’Djamena, Chad, were performed by single-platform, volumetric, CD45-assisted pan-leucogating Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) comparing to the FACSCalibur flow cytometer as a reference method.ResultsAbsolute and percentage CD4 T cell counts obtained by Auto40 and FACSCalibur of 258 HIV-1-infected blood samples were highly correlated (r = 0.99 and r = 0.96, respectively). The mean absolute bias and percent bias between Apogee Auto40 and FACSCalibur absolute CD4 T cell counts, were −9.4 cells/μl with limits of agreement from −15 to 93 cells/μl, and +2.0% with limits of agreement from −0.9 to 4.9%, respectively. The mean of absolute bias and percent bias between Apogee Auto40 and FACSCalibur of CD4 percentage results were +0.4% (95% CI: -0.02 – 0.86) with limits of agreement from −2.4 to 0.3%, and +3.0% with limits of agreement from −6.6 to 0.6%, respectively. The Auto40 counting allowed to identify the majority of adults with CD4 T cells below 200 cells/μl (sensitivity: 89%; specificity: 99%) or below 350 cells/μl (sensitivity: 94%; specificity:98%); and of children below 750 cells/μl (sensitivity: 99%; specificity: 96%) or below 25% CD4+ (sensitivity: 94%; specificity: 98%).ConclusionThe Auto40 analyzer is an alternative flow cytometer for CD4 T lymphocyte enumeration to be used in routine for immunological monitoring according to the current WHO recommendations in HIV-infected adults as well as children living in resource-constrained settings like Chad.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.