This paper presents an approach of empirical modeling of the machining process physical quantity with measurement uncertainty parameter included in the resulting power mathematical model coefficients. The proposed approach is presented through an example of modeling of the average temperature in turning like a methodology that is under the influence of various sources of measurement errors. The uncertainty budget accounts for the sources of errors of the experimental measuring system and the cutting process itself. This approach enables estimation of the reliability of the gained mathematical models and gives the possibility of identification and lowering of the main sources of errors.
This paper presents an approach of empirical modeling of cutting process physical phenomena with measurement uncertainty parameters accompanied to the model exponents/ /coefficients. The approach is presented trough an example of creating a power mathematical model for average cutting temperature in turning with details about the uncertainty contributions from different experimental plans. The approach is proposed to be implemented as usual practice during empirical modeling, in order the resulting models to fit with the needs of the smart machining systems and the needs of interoperability between researchers.
The presence of some chemical compounds at higher levels than maximum permissible concentrations (MPC) in the drinking water, suggests of water resources pollution. In this paper the following elements were analyzed: total arsenic, cadmium, lead, cooper and zinc. Twelve samples of water from the water supply system from the city of Skopje were examined during one year from three different springs. Also, ten samples of bottled water from three producers from the Macedonian market were tested.The determined average mass concentrations of total As, Cd(II), Pb(II), Cu(II) and Zn(II) in the analyzed water samples from the water supply system are 1.35 μg/l, 0.06 μg/l, 0.6 μg/l, 0.9 μg/l and 1,12 μg/l, respectively, and for the tested bottled water, the mean values ranges from 0.56 - 0.83 μg total As / l, 0.053 - 0.056 μg Cd(II)/l, 0.51 - 0.54 μg Pb(II)/l , 0.6 - 0.87 μg Cu(II)/l and 0.68 - 0.8 μg Zn(II)/l water.The following instrumental analytical methods and techniques were used for the analysis of the tested samples of drinking water: flame atomic absorption spectroscopy (AAS), atomic absorption spectroscopy with hydride cеll, electrothermal atomic absorption spectroscopy.The obtained results are shown in tables and graphic form. According to the obtained results a comparative analysis was carried out indicate that it is a water of good quality that can be used in different branches of the process industry.The obtained results in this paper do not exceed the values of the MPC of the Republic of Macedonia prescribed by the legal regulations for the drinking water, which confirm the health safety of the drinking water from the water supply system in the city of Skopje and the packed waters from the Macedonian market in relation to the tested elements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.