PT and aPTT cannot be interchangeably used with ROTEM(®) CT. Based on the results of ROTEM(®), recommended thresholds for PT and aPTT might overestimate the need for coagulation therapy. A good correlation was found between the fibrinogen level and the FibTEM assay. In addition, ROTEM(®) offered faster turnaround times.
The tapered PU tube cuff was as effective as the cylindrical PU cuffs in smaller tracheal diameters and was more efficient than the cylindrical Microcuff PU tube cuff in larger tracheal diameter in preventing subglottic fluid leakage across the tube cuff tested in this in vitro study. PVC tube cuffs leaked much more and faster than PU cuffs.
BACKGROUND: Hypofibrinogenaemia is one of the main reasons for development of perioperative coagulopathy during major paediatric surgery. The aim of this study was to assess whether prophylactic maintenance of higher fibrinogen concentrations through administration of fibrinogen concentrate would decrease the volume of transfused red blood cell (RBCs). METHODS: In this prospective, randomised, clinical trial, patients aged 6 months to 17 yr undergoing craniosynostosis and scoliosis surgery received fibrinogen concentrate (30 mg kg(-1)) at two predefined intraoperative fibrinogen concentrations [ROTEM(®) FIBTEM maximum clot firmness (MCF) of <8 mm (conventional) or <13 mm (early substitution)]. Total volume of transfused RBCs was recorded over 24 h after start of surgery. RE-SULTS: Thirty children who underwent craniosynostosis surgery and 19 children who underwent scoliosis surgery were treated per protocol. During craniosynostosis surgery, children in the early substitution group received significantly less RBCs (median, 28 ml kg(-1); IQR, 21 to 50 ml kg(-1)) compared with the conventional fibrinogen trigger of <8 mm (median, 56 ml kg(-1); IQR, 28 to 62 ml kg(-1)) (P=0.03). Calculated blood loss as per cent of estimated total blood volume decreased from a median of 160% (IQR, to a median of 90% (IQR, 78-110%) (P=0.017). No significant changes were observed in the scoliosis surgery population. No bleeding events requiring surgical intervention, postoperative transfusions of RBCs, or treatment-related adverse events were observed. CONCLUSIONS: Intraoperative administration of fibrinogen concentrate using a FIBTEM MCF trigger level of <13 mm can be successfully used to significantly decrease bleeding, and transfusion requirements in the setting of craniosynostosis surgery, but not scoliosis. CLINICAL TRIAL REGISTRY NUMBER: ClinicalTrials.gov NCT01487837. AbstractBackground: Hypofibrinogenaemia is one of the main reasons for development of perioperative coagulopathy during major paediatric surgery. The aim of this study was to assess whether prophylactic maintenance of higher fibrinogen concentrations through administration of fibrinogen concentrate would decrease the volume of transfused red blood cell (RBCs). Methods: In this prospective, randomised, clinical trial, patients aged 6 months to 17 yr undergoing craniosynostosis and scoliosis surgery received fibrinogen concentrate (30 mg kg
BackgroundModerate to severe intraoperative bleeding and the presence of acquired coagulopathy remain serious problems in the management of major pediatric craniosynostosis surgery. After implementation of a ROTEM®-assisted patient blood management (PBM) strategy, using primarily purified coagulation factor concentrates, feasibility and costs of this new regimen were analyzed.MethodsRetrospective analysis of all consecutive children who underwent primary elective major craniofacial surgery for craniosynostosis repair was carried out at the Children's University Hospital, Zurich, between 2007 and 2013. Laboratory workup and transfusion requirements were compared.ResultsA total of 47 children (36 in the historic group and 11 after implementation of PBM) were analyzed. Although all patients in this study needed transfusion of red blood cell concentrates, there was a total avoidance of perioperative transfusion of fresh frozen plasma and a reduction in transfused platelets (one of nine children vs nine of 36 children in the historic group) after implementation of the PBM strategy. Based on a predefined ROTEM® threshold in the PBM group (FibTEM MCF <8 mm), administration of fibrinogen concentrate was necessary in all of these children. The mean total costs per patient consisting of transfused allogeneic blood products and coagulation factor concentrates were reduced by 17.1% after implementation of PBM (1071.82 EUR per patient before vs 888.93 EUR after implementation).ConclusionsThe implementation of a ROTEM®-assisted PBM is feasible and is associated with a considerable reduction in intraoperative transfusion requirements and thereby a decrease in transfusion-related direct costs.
Background. Thromboelastometry (ROTEM(R)) might be useful to detect intraoperative coagulation disorders early in major paediatric surgery. This observational trial compares this technique to standard coagulation tests. Methods. Intraoperative blood sampling was obtained in children undergoing elective major surgery. At each time point, standard coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen level] and ROTEM(R) analyses (InTEM, ExTEM, and FibTEM) were performed simultaneously by trained hospital laboratory staff. Results. A total of 288 blood samples from 50 subjects were analysed. While there was a poor correlation between PT and aPTT to ExTEM clotting time (CT) and InTEM CT, respectively, a good correlation was detected between PT and aPTT to clot formation time, and a very good correlation between fibrinogen level and FibTEM assay (r=0.882, P<0.001). Notably, 64% of PT and 94% of aPTT measurements were outside the reference range, while impaired CT was observed in 13% and 6.3%, respectively. Standard coagulation test results were available after a median of 53 min [inter-quartile range (IQR): 45-63 min], whereas 10 min values of ROTEM(R) results were available online after 23 min (IQR: 21-24 min). Conclusions. PT and aPTT cannot be interchangeably used with ROTEM(R) CT. Based on the results of ROTEM(R), recommended thresholds for PT and aPTT might overestimate the need for coagulation therapy. A good correlation was found between the fibrinogen level and the FibTEM assay. In addition, ROTEM(R) offered faster turnaround times.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.