BackgroundExperimental studies have suggested that end‐ischaemic dual hypothermic oxygenated machine perfusion (DHOPE) may restore hepatocellular energy status and reduce reperfusion injury in donation after circulatory death (DCD) liver grafts. The aim of this prospective case–control study was to assess the safety and feasibility of DHOPE in DCD liver transplantation.MethodsIn consecutive DCD liver transplantations, liver grafts were treated with end‐ischaemic DHOPE. Outcome was compared with that in a control group of DCD liver transplantations without DHOPE, matched for donor age, donor warm ischaemia time, and recipient Model for End‐stage Liver Disease (MELD) score. All patients were followed for 1 year.ResultsTen transplantations involving liver grafts treated with DHOPE were compared with 20 control procedures. There were no technical problems. All 6‐month and 1‐year graft and patient survival rates were 100 per cent in the DHOPE group. Six‐month graft survival and 1‐year graft and patient survival rates in the control group were 80, 67 and 85 per cent respectively. During DHOPE, median (i.q.r.) hepatic adenosine 5′‐triphosphate (ATP) content increased 11‐fold, from 6 (3–10) to 66 (42–87) µmol per g protein (P = 0·005). All DHOPE‐preserved livers showed excellent early function. At 1 week after transplantation peak serum alanine aminotransferase (ALT) and bilirubin levels were twofold lower in the DHOPE group than in the control group (ALT: median 966 versus 1858 units/l respectively, P = 0·006; bilirubin: median 1·0 (i.q.r. 0·7–1·4) versus 2·6 (0·9–5·1) mg/dl, P = 0·044). None of the ten DHOPE‐preserved livers required retransplantation for non‐anastomotic biliary stricture, compared with five of 20 in the control group (P = 0·140).ConclusionThis clinical study of end‐ischaemic DHOPE in DCD liver transplantation suggests that the technique restores hepatic ATP, reduces reperfusion injury, and is safe and feasible. RCTs with larger numbers of patients are warranted to assess the efficacy in reducing post‐transplant biliary complications.
In contrast to traditional static cold preservation of donor livers, normothermic machine perfusion may reduce preservation injury, improve graft viability and potentially allows ex vivo assessment of graft viability before transplantation. We have studied the feasibility of normothermic machine perfusion in four discarded human donor livers. Normothermic machine perfusion consisted of pressure and temperature controlled pulsatile perfusion of the hepatic artery and continuous portal perfusion for 6 h. Two hollow fiber membrane oxygenators provided oxygenation of the perfusion fluid. Biochemical markers in the perfusion fluid reflected minimal hepatic injury and improving function. Lactate levels decreased to normal values, reflecting active metabolism by the liver (mean lactate 10.0 ± 2.3 mmol/L at 30 min to 2.3 ± 1.2 mmol/L at 6 h). Bile production was observed throughout the 6 h perfusion period (mean rate 8.16 ± 0.65 g/h after the first hour). Histological examination before and after 6 h of perfusion showed well-preserved liver morphology without signs of additional hepatocellular ischemia, biliary injury or sinusoidal damage. In conclusion, this study shows that normothermic machine perfusion of human donor livers is technically feasible. It allows assessment of graft viability before transplantation, which opens new avenues for organ selection, therapeutic interventions and preconditioning.
Although normothermic machine perfusion of donor livers may allow assessment of graft viability prior to transplantation, there are currently no data on what would be a good parameter of graft viability. To determine whether bile production is a suitable biomarker that can be used to discriminate viable from non-viable livers we have studied functional performance as well as biochemical and histological evidence of hepatobiliary injury during ex vivo normothermic machine perfusion of human donor livers. After a median duration of cold storage of 6.5 h, twelve extended criteria human donor livers that were declined for transplantation were ex vivo perfused for 6 h at 37°C with an oxygenated solution based on red blood cells and plasma, using pressure controlled pulsatile perfusion of the hepatic artery and continuous portal perfusion. During perfusion, two patterns of bile flow were identified: (1) steadily increasing bile production, resulting in a cumulative output of ≥30 g after 6 h (high bile output group), and (2) a cumulative bile production <20 g in 6 h (low bile output group). Concentrations of transaminases and potassium in the perfusion fluid were significantly higher in the low bile output group, compared to the high bile output group. Biliary concentrations of bilirubin and bicarbonate were respectively 4 times and 2 times higher in the high bile output group. Livers in the low bile output group displayed more signs of hepatic necrosis and venous congestion, compared to the high bile output group. In conclusion, bile production could be an easily assessable biomarker of hepatic viability during ex vivo machine perfusion of human donor livers. It could potentially be used to identify extended criteria livers that are suitable for transplantation. These ex vivo findings need to be confirmed in a transplant experiment or a clinical trial.
Two hours of oxygenated HMP after traditional SCS restores hepatic ATP levels and improves hepatobiliary function but does not reduce (preexisting) hepatobiliary injury in ECD livers.
BackgroundLivers derived from donation after circulatory death (DCD) are increasingly accepted for transplantation. However, DCD livers suffer additional donor warm ischemia, leading to biliary injury and more biliary complications after transplantation. It is unknown whether oxygenated machine perfusion results in better preservation of biliary epithelium and the peribiliary vasculature. We compared oxygenated hypothermic machine perfusion (HMP) with static cold storage (SCS) in a porcine DCD model.MethodsAfter 30 min of cardiac arrest, livers were perfused in situ with HTK solution (4°C) and preserved for 4 h by either SCS (n = 9) or oxygenated HMP (10°C; n = 9), using pressure-controlled arterial and portal venous perfusion. To simulate transplantation, livers were reperfused ex vivo at 37°C with oxygenated autologous blood. Bile duct injury and function were determined by biochemical and molecular markers, and a systematic histological scoring system.ResultsAfter reperfusion, arterial flow was higher in the HMP group, compared to SCS (251±28 vs 166±28 mL/min, respectively, after 1 hour of reperfusion; p = 0.003). Release of hepatocellular enzymes was significantly higher in the SCS group. Markers of biliary epithelial injury (biliary LDH, gamma-GT) and function (biliary pH and bicarbonate, and biliary transporter expression) were similar in the two groups. However, histology of bile ducts revealed significantly less arteriolonecrosis of the peribiliary vascular plexus in HMP preserved livers (>50% arteriolonecrosis was observed in 7 bile ducts of the SCS preserved livers versus only 1 bile duct of the HMP preserved livers; p = 0.024).ConclusionsOxygenated HMP prevents arteriolonecrosis of the peribiliary vascular plexus of the bile ducts of DCD pig livers and results in higher arterial flow after reperfusion. Together this may contribute to better perfusion of the bile ducts, providing a potential advantage in the post-ischemic recovery of bile ducts.
contributed equally to this work.Abbreviations: ADP, adenosine diphosphate; AMP, adenosine monophosphate; ATP, adenosine triphosphate; CIT, cold ischemia time; DBD, donation after brain death; DCD, donation after circulatory death; FENa, fractional excretion of sodium; HBOC, hemoglobin-based oxygen carrier; HMP, hypothermic machine perfusion; NEDS, New England Donor Services; NEVKP, normothermic ex vivo kidney perfusion; NMP, normothermic machine perfusion; PRBC, packed red blood cells; QAS, quality assessment score; SCS, static cold storage; WIT, warm ischemia time.Normothermic machine perfusion presents a novel platform for pretransplant assessment and reconditioning of kidney grafts. Maintaining the metabolic activity of a preserved graft at physiologic levels requires an adequate oxygen supply, typically delivered by crystalloid solutions supplemented with red blood cells. In this study, we explored the feasibility of using a synthetic hemoglobin-based oxygen carrier (HBOC) in human kidney normothermic perfusion. Fourteen discarded human kidneys were perfused for 6 hours at a mean temperature of 37°C using a pressurecontrolled system. Kidneys were perfused with a perfusion solution supplemented with either HBOC (n = 7) or packed red blood cells (PRBC) (n = 7) to increase oxygencarrying capacity. Renal artery resistance, oxygen extraction, metabolic activity, energy stores, and histological features were evaluated. Throughout perfusion, kidneys from both groups exhibited comparable behavior regarding vascular flow (P = .66), oxygen consumption (P = .88), and reconstitution of tissue adenosine triphosphate (P = .057). Lactic acid levels were significantly higher in kidneys perfused with PRBC (P = .007). Histological findings were comparable between groups, and there was no evidence of histological damage caused by the HBOC. This feasibility experiment demonstrates that a HBOC solution can offer a logistically more convenient off-theshelf alternative to PRBC in normothermic machine perfusion of human kidneys. K E Y W O R D Sbasic (laboratory) research/science, kidney transplantation/nephrology, organ perfusion and preservation, organ procurement and allocation, tissue/organ engineering, translational research/science | 2815 ABURAWI et Al.
Although normothermic machine perfusion of donor livers may allow assessment of graft viability prior to transplantation, there are currently no data on what would be a good parameter of graft viability. To determine whether bile production is a suitable biomarker that can be used to discriminate viable from non-viable livers we have studied functional performance as well as biochemical and histological evidence of hepatobiliary injury during ex vivo normothermic machine perfusion of human donor livers. After a median duration of cold storage of 6.5 h, twelve extended criteria human donor livers that were declined for transplantation were ex vivo perfused for 6 h at 37uC with an oxygenated solution based on red blood cells and plasma, using pressure controlled pulsatile perfusion of the hepatic artery and continuous portal perfusion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers