BACKGROUND: Chronic entrapment neuropathy results in a clinical syndrome ranging from mild pain to debilitating atrophy. There remains a lack of objective metrics that quantify nerve dysfunction and guide surgical decision-making. Mechanomyography (MMG) reflects mechanical motor activity after stimulation of neuromuscular tissue and may indicate underlying nerve dysfunction. OBJECTIVE: To evaluate the role of MMG as a surgical adjunct in treating chronic entrapment neuropathies. METHODS: Patients 18 years or older with cubital tunnel syndrome (n = 8) and common peroneal neuropathy (n = 15) were enrolled. Surgical decompression of entrapped nerves was performed with intraoperative MMG of the hypothenar and tibialis anterior muscles. MMG stimulus thresholds (MMG-st) were correlated with compound muscle action potential (CMAP), motor nerve conduction velocity, baseline functional status, and clinical outcomes. RESULTS: After nerve decompression, MMG-st significantly reduced, the mean reduction of 0.5 mA (95% CI: 0.3-0.7, P < .001). On bivariate analysis, MMG-st exhibited significant negative correlation with common peroneal nerve CMAP (P < .05), but no association with ulnar nerve CMAP and motor nerve conduction velocity. On preoperative electrodiagnosis, 60% of nerves had axonal loss and 40% had conduction block. The MMG-st was higher in the nerves with axonal loss as compared with the nerves with conduction block. MMG-st was negatively correlated with preoperative hand strength (grip/pinch) and foot-dorsiflexion/toe-extension strength (P < .05). At the final visit, MMG-st significantly correlated with pain, PROMIS-10 physical function, and Oswestry Disability Index (P < .05). CONCLUSION: MMG-st may serve as a surgical adjunct indicating axonal integrity in chronic entrapment neuropathies which may aid in clinical decision-making and prognostication of functional outcomes.
Introduction/Aims Although therapeutic electrical stimulation (TES) of injured peripheral nerve promotes axon regeneration and functional recovery, clinical applications of this therapy are limited to the intraoperative timeframe. Implantable, thin‐film wireless nerve stimulators offer a potential solution to this problem by enabling delivery of electrical stimuli to an injured nerve over a period of several days post‐surgery. The aim of this study was to determine the optimal time course of stimulation for maximizing functional recovery in a rat sciatic nerve isograft repair model. Methods Adult male Lewis rats underwent thin‐film wireless nerve stimulator implantation following sciatic nerve transection and 40 mm nerve isograft repair. Immediately after surgery, animals began a daily regimen of TES for up to 12 consecutive days. Functional recovery was assessed by compound muscle action potential (CMAP), evoked muscle force, wet muscle mass, and axon counting. Results Serial CMAP measurements increased in amplitude over the course of the study, yet no significant difference between cohorts for serial or terminal CMAPs was observed. Axon counts and wet muscle mass measurements were greatest in the 6‐day stimulation group, which correlated with a significant increase in evoked muscle force for the 6‐day stimulation group at the terminal time point. Discussion Six daily sessions of TES were found to be most effective for augmenting functional recovery compared to other time courses of stimulation. Future studies should incorporate additional subjects and track axonal sprouting or measure neurotrophin levels during the therapeutic window to further elucidate the mechanisms behind, and ideal amount of, TES.
Background and objective High-frequency alternating current (HFAC) can yield a rapid-acting and reversible nerve conduction block. The present study aimed to demonstrate the successful implementation of HFAC block delivery via regenerative macro-sieve electrodes (MSEs). Methods Dual-electrode assemblies in two configurations [dual macro-sieve electrode-1 (DMSE-I), DMSE-II] were fabricated from pairs of MSEs and implanted in the transected and subsequently repaired sciatic nerves of two male Lewis rats. After four months of postoperative nerve regeneration through the MSEs' transit zones, the efficacy of acute HFAC block was tested for both configurations. Frequencies ranging from 10 kHz to 42 kHz, and stimulus amplitudes with peak-to-peak voltages ranging from 2 V to 20 V were tested. Evoked muscle force measurement was used to quantify the nerve conduction block. Results HFAC stimulation delivered via DMSE assemblies obtained a complete block at frequencies of 14 to 26 kHz and stimulus amplitudes of 12 to 20 V p-p. The threshold voltage for the complete block showed an approximately linear dependence on frequency. The threshold voltage for the partial conduction block was also approximately linear. For those frequencies that displayed both partial and complete block, the partial block thresholds were consistently lower. Conclusion This study provides a proof of concept that regenerative MSEs can achieve complete and reversible conduction block via HFAC stimulation of regenerated nerve tissue. A chronically interfaced DMSE assembly may thereby facilitate the inactivation of targeted nerves in cases wherein pathologic neuronal hyperactivity is involved.
Macro-sieve electrodes were implanted in the sciatic nerve of five adult male Lewis rats following spinal cord injury to assess the ability of the macro-sieve electrode to interface regenerated peripheral nerve fibers post-spinal cord injury. Each spinal cord injury was performed via right lateral hemisection of the cord at the T9–10 site. Five months post-implantation, the ability of the macro-sieve electrode to interface the regenerated nerve was assessed by stimulating through the macro-sieve electrode and recording both electromyography signals and evoked muscle force from distal musculature. Electromyography measurements were recorded from the tibialis anterior and gastrocnemius muscles, while evoked muscle force measurements were recorded from the tibialis anterior, extensor digitorum longus, and gastrocnemius muscles. The macro-sieve electrode and regenerated sciatic nerve were then explanted for histological evaluation. Successful sciatic nerve regeneration across the macro-sieve electrode interface following spinal cord injury was seen in all five animals. Recorded electromyography signals and muscle force recordings obtained through macro-sieve electrode stimulation confirm the ability of the macro-sieve electrode to successfully recruit distal musculature in this injury model. Taken together, these results demonstrate the macro-sieve electrode as a viable interface for peripheral nerve stimulation in the context of spinal cord injury.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.