Studies in which an independent, blinded comparison is made with a valid reference standard among consecutive patients are yet to be undertaken. There should also be an agreed ICP test protocol for diagnosing CECS because the variability here contributes to the large differences in ICP measurements and hence diagnostic thresholds between studies. Current ICP pressure criteria for CECS diagnosis are therefore unreliable, and emphasis should remain on good history. However, clinicians may consider measurements taken at 1 minute after exercise because mean levels at this timing interval only did not overlap between subjects and controls in the studies we analyzed. Levels above the highest reported value for controls here (27.5 mm Hg) along with a good history, should be regarded as highly suggestive of CECS. It is evident that to achieve an objective recommendation for ICP threshold there is a need to set up a multi-center study group to reach an agreed testing protocol and modify the preliminary recommendations we have made.
High volume injections to mechanically disrupt the neovascularisation in patellar tendinopathy are helpful in the management of this condition. Controlled trials would be warranted to investigate in a more conclusive fashion this management modality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.