Background-The addition of a mitral isthmus (MI) block line after pulmonary vein isolation could lead to a favorable outcome of catheter ablation in patients with atrial fibrillation (AF). However, it is sometimes tough to create a complete MI block line, and the cooling effect because of the local coronary flow may prevent the creation of a successful MI block line. Methods and Results-This study enrolled 81 AF patients in whom the creation of an MI block line was attempted in those with persistent or pacing-inducible AF after pulmonary vein isolation. A local coronary artery (LCA) across the MI block line was observed in 43 (53%) of 81 patients, and a bidirectional MI block was successfully accomplished in 53 (65%) of 81 patients, at the estimated MI line. The ratio of a successful MI block line was significantly lower in the patients with an LCA than in those without an LCA (42% versus 92%; PϽ0.001). The mean diameter of the coronary sinus (0.59Ϯ0.18 versus 0.82Ϯ0.22 cm; PϽ0.001) and length of the estimated MI line (33.4Ϯ9.9 versus 29.4Ϯ7.1 mm; Pϭ0.032) were significantly shorter in the patients with a successful MI block line than in those without a successful MI block line. In the multivariable analysis, an LCA at the MI and a larger coronary sinus diameter were independent risk factors for an unsuccessful MI block line. Conclusions-Local coronary flow at the MI is associated with an increased incidence of an unsuccessful MI block line.(Circ Arrhythm Electrophysiol. 2011;4:838-843.)
urpose: To describe a novel technique using an antegrade wire in a retrograde microcatheter advanced through a transcollateral vessel for recanalization of challenging infrapopliteal chronic total occlusions. Technique: A 75-year-old diabetic man presented with critical limb ischemia manifested as nonhealing ulcers on the toes. Baseline angiography revealed a blunt, long, total occlusion of the anterior tibial artery. A retrograde microcatheter was advanced over a guidewire tracking the collateral channel from the planter artery. Antegrade and retrograde microcatheters were aligned inside the occluded lesion. An antegrade wire was then advanced further down through the retrograde microcatheter. Final angiography of the anterior tibial artery following balloon dilation demonstrated a satisfactory result, without evidence of significant residual stenoses or flow-limiting dissections. Complete wound healing was achieved at 3 weeks. Conclusion: This alternative wire method may be useful when traditional interventional approaches are unfeasible.
The geometric AVA is smaller with 3D-TEE than with 2D-TEE, and the difference is not due to the lower frame rate of 3D-TEE. The improved accuracy of 3D-TEE along with reduced image acquisition time indicates that 3D-TEE is superior to 2D-TEE for the assessment of AVA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.