Aiming at a totally implantable ventricular assist device (VAD), a vibrating flow pump (VFP) was developed in Tohoku University. A transcutaneous energy transmission system (TETS) using an amorphous fiber was developed for the totally implantable VAD system. The VFP works with a higher frequency than the natural heart of a biological system, a frequency of 10-50 Hz. In this research, animal experiments on left heart bypass were performed with healthy goats. Blood from the apex of the left ventricle was received and was sent to the aorta so that an adequate supporting effect of the left heart was provided. In particular, the depression effect of the left ventricle was obvious. As a result, sufficient artificial heart flow was provided. For a totally implantable type VAD, left heart bypass of almost 100% may become necessary in some situations. Therefore, apex approaches of left heart bypass may be desirable. From an anatomical consideration, an apex of the heart is suitable for the VFP of this totally implantable type. In the left heart bypass for which the apex of the heart was used, an almost 100% bypass was possible. This is a requirement that is important when waiting for recovery of sufficient cardiac function. It is also important that left heart circulation is maintained fully by an artificial heart of the complete implantation type. The VFP was considered to be useful as a totally implantable type artificial heart from the results.
For development aimed at a totally implantable type ventricular assist device (VAD), the vibrating flow pump (VFP) has been developed at Tohoku University. A transcutaneous energy transmission system (TETS) using amorphous fibers was developed to power the totally implantable VAD system. The VFP works at a high frequency compared to that of a natural heart of a biological system. It is a frequency of 10-50 Hz. In this research, animal experiments with left heart bypass were carried out with healthy adult goats. For comparison between nonpulsatile flow and oscillated flow, a rotary pump (RP) and the VFP were used in the experiments. For the achievement of total left heart bypass, left ventricular approaches were carried out, and blood was pumped from the left ventricle to the descending aorta. Adequate support of the left heart was provided by both pumps. In terms of the results, the vascular resistances tended to decrease during the use of both pumps during 100% bypass driving. When we compared these pumps at the same flow rate, the resistances during RP driving were significantly smaller than those during VFP driving. These results may suggest that the influences of the VFP upon the peripheral vessels may be relatively small compared to those of the RP. This may be an important result when a stable hemodynamic condition is required during artificial circulation. The VFP was considered as a candidate for a totally implantable VAD as a result.
Nonlinearity in circulation control attracts attention because nonlinearity is thought to be essential in the function of the living body. Many investigators have pointed out that the analysis of heart rate variability in particular is important in the analysis of autonomic nerve and cardiac function evaluation. Heart rate variability shows nonlinear behavior. However, until the present, many reports have been premised on linearity; linear correlation by frequency analysis has been used by many studies. However, in terms of this methodology, there is a problem applying it to the nonlinear living body. Therefore, fractal and chaos methodology has been used. The ascertainment of cardiac function has become important in allowing the clinical stage of a ventricular assist system to be successful. The purpose of this study was cardiac function evaluation by a methodology that was premised on nonlinearity. Chaos and fractal theory was used as a nonlinear dynamic theory. As a methodology of measurement, the volume of the left ventricle was used rather than an electrocardiogram, the waveform of arterial blood pressure. The volume was measured using acoustic quantification (AQ) ultrasonic echocardiography. Using these methodologies, the time series of many patients were analyzed. For example, drug administration was attempted in this study, and it was found that some drugs like ACE inhibitors showed a significant effect upon nonlinear dynamics in the cardiovascular system. The result, which attempted cardiac function evaluation by these various methodologies, is reported.
In the clinical usage of the ventricular assist device (VAD), multiple organ failure becomes an important problem. To improve the clinical record of the VAD, another organ function may be vitally important. For that reason, we have been developing a VAD system aiming at improving another organ's function. Development of the vibrating flow pump (VFP), which can generate a very unique flow pattern from 10 Hz to 50 Hz, was ongoing in our Institute. In order to evaluate brain blood flow and oxygen consumption, HbO2 was measured with a NIRO monitoring device in healthy adult goats. Four goats were anesthetized with halothane inhalation; then left thoracotomy was performed for the left heart bypass. HbO2 of the brain was measured by recording of the hemodynamic variables during left heart assistance with the VFP system. During left heart bypass with the VFP system, hemodynamic parameters stayed within normal range, and satisfactory pump output was easily obtained. Pump output stayed within 20-40% bypass to evaluate the effect of high frequency oscillated assist flow on brain blood flow during the same cardiac output. Interesting results were observed during the experiments. During 30 Hz drive of the VFP left heart assistance, HbO2 suggested that brain blood flow significantly increased compared with another drive frequency assistance during the same total cardiac output. These results suggest that we can control the brain blood flow with a totally implantable VAD system such as the VFP system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.