After ethics committee approval, 51 consenting ASA physical status 1 or 2 adult patients were given basal flow sevoflurane anaesthesia using fresh gas flows of 150 to 300 ml.min-1 oxygen. A Komesaroff vaporizer was placed on the inspiratory limb of the circle system. Basal flows were introduced immediately following intravenous induction of anaesthesia. The vaporizer was set to deliver the maximum concentration until the inspired sevoflurane concentration (FSI) reached 3%. The dial was then adjusted to maintain the FSI at 3%. After every 60 minutes, the circuit was washed out with 100% oxygen at a flow rate of 10 l.min-1 for one minute. The FSI reached 3% after an average of 8.5 (3.8) [mean (SD)] minutes. The trends in FSI and the expired sevoflurane concentrations were significantly different (P<0.05) between the mechanically ventilated patients (n=21) and the spontaneously ventilating patients (n=30) and demonstrated a more gradual build-up in the former group. The consumption of sevoflurane was found to be 9.2 (2.8) ml.h-1. This represented a 52.5% cost saving over the clinical application of the Mapleson's ideal fresh gas flow sequence for low-flow anaesthesia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.