The use of different chelating agents did not influence the push-out bond strength of endodontic sealers. Calcium silicate-based sealers had lower push-out bond strength values compared with a conventional epoxy resin-based sealer (AH Plus).
Push-out bond strength of MTA HP, a new high-plasticity calcium silicate-based cement Abstract: This study was designed to investigate the resistance to dislodgment provided by MTA HP, a new high-plasticity calcium silicate-based cement. Biodentine and White MTA Angelus were used as reference materials for comparison. Three discs 1 ± 0.1 mm thick were obtained from the middle third of the roots of 5 maxillary canines. Three 0.8-mm-wide holes were drilled on the axial surface of each root disc. Standardized irrigation was performed. Then the holes were dried with paper points and filled with one of the three tested cements. The filled dental slices were immersed in a phosphate-buffered saline (PBS) solution (pH 7.2) for 7 days before the push-out assessment. The Kruskal-Wallis test was applied to assess the effect of each endodontic cement on the push-out bond strength. Mann-Whitney with Bonferroni correction was used to isolate the differences. The alpha-type error was set at 0.05. All specimens had measurable push-out values and no premature failure occurred. There were significant differences among the materials (p <0.05). The Biodentine specimens had the highest push-out bond strength values (p < 0.05). MTA HP had significantly higher bond strength than White MTA (p < 0.05). MTA HP showed better push-out bond strength than its predecessor, White MTA; however, Biodentine had higher dislodgment resistance than both MTA formulations.
This study investigated the bond strength of two experimental root canal sealers based on MTA and butyl ethylene glycol disalicylate: MTAe and MTAe-HA. The reference materials used for comparison were AH Plus and MTA Fillapex. Twenty human upper incisors were selected and one 1 mm slice was obtained from the cervical third of each root. On the coronal surface of each slice, four 0.9 mm wide holes were drilled through the dentine. Standardized irrigation was performed and holes were filled with one of the four tested sealers: AH Plus, MTA Fillapex, MTAe, and MTAe-HA. The filled slices were stored in a PBS solution (pH 7.2) for 7 days at 37 °C. A push-out assessment was performed with a 0.7 mm plunger tip. Load was applied at a crosshead speed of 0.5 mm/min until sealer displacement. The results were expressed in MPa. The Kruskal-Wallis test was applied to assess the effect of each sealer on the push-out bond strength. Mann-Whitney with Bonferroni correction was used to isolate the differences. The alpha-type error was set at 0.05. Significant differences among medians values obtained by materials were observed (p<0.001). AH Plus displayed the highest value of bond strength (p<0.001). In contrast, MTA Fillapex presented the lowest bond strength among all tested sealers (p<0.001). Experimental sealers showed intermediary bond strength values, with no statistical differences between them (p>0.05). In conclusion, experimental root canal sealers presented suitable bond strength outcomes when compared to MTA Fillapex.
Aim
To investigate the reliability of using bovine teeth as an alternative to human teeth in an intra‐tooth push‐out model by comparing the bond strength of three root canal sealers in both tooth substrates.
Methodology
From human and bovine incisors (12 per group), one 1‐mm disc was obtained from each root. On each disc, three standard 0.8‐mm‐diameter holes were drilled through the dentine. After irrigation, the holes were filled with one of three root canal sealers: AH Plus, MTA Fillapex or Total Fill BC Sealer. Tooth slices were kept in contact with sterile gauze moistened in PBS solution (pH = 7.2) for 7 days at 37 °C, and finally, a push‐out load was applied until sealer dislocation. The bonded interface area was calculated to obtain data in MPa. The push‐out data for each sealer and the overall push‐out data for human and bovine teeth were compared (Mann–Whitney U). Kruskal–Wallis was used to study the sealers behaviour at each of the dental substrates. Multiple comparisons were performed using Mann–Whitney U after Bonferroni correction (P < 0.05).
Results
Dentine substrate did not influence the push‐out of either individual sealers or overall sealers tested (Mann–Whitney U, P > 0.05). In both human and bovine samples, AH Plus performed better than BC Sealer and MTA Fillapex, whilst BC Sealer also provided a superior push‐out compared to MTA Fillapex (Mann–Whitney U, P < 0.05).
Conclusion
When using an intra‐tooth model, bovine teeth did not significantly influence the bond strength of sealers.
The aim of the present study was to evaluate the cytotoxic effects of five endodontic sealers (AH Plus, Endomethasone N, EndoSequence BC, MTA Fillapex and Pulp Canal Sealer EWT) using a three-dimensional (3D) cell culture model. A conventional bi-dimensional (2D) cell culture model was used as reference technique for comparison. Balb/c 3T3 fibroblasts were cultured in conventional bi-dimensional cell culture and in rat-tail collagen type I three-dimensional cell culture models. Then, both cell cultures were incubated with elutes of freshly mixed endodontic sealers for 24 h. Cell viability was measured by the methyl-thiazol-diphenyltetrazolium assay (MTT). Data were statistically analyzed using ANOVA and the Tukey test at a significance level of p<0.05. All tested sealers exhibited cytotoxic effects; however, cytotoxic effect was culture model- and sealer-dependent. Sealers showed higher cytotoxicity in 2D than in 3D cell culture model (p<0.05). In both conditions, EndoSequence BC showed the lowest cytotoxicity (p<0.05). MTA Fillapex was much more cytotoxic than the other tested endodontic sealers (p<0.05), with the exception of AH Plus in the 2D cell culture model (p>0.05). Endomethasone N and Pulp Canal Sealer EWT showed lower cytotoxic effects than AH Plus in 2D cell culture model (p<0.05); however no statistical differences was observed among these sealers in 3D cell culture model. It may be concluded that cytotoxicity was higher in 2D cell culture compared to 3D cell culture. EndoSequence BC sealer exhibited the highest cytocompatibility and MTA Fillapex the lowest cytocompatibility.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.