This study discusses the components' geometry and its effect on the capability of heat transmission and pressure drop because of its evident influence on the performance of micro capillary pumped loop (MCPL). On analyzing the dimensional effect on heat transmission and pressure gradient of MCPL device, some results were yielded and addressed as follows: The vapor line was the most important factor among the components of MCPL in heat transmission and pressure drop. Furthermore, the depth of vapor line was the main parameter because of its drastic effect. In addition, at depth of vapor line, h v , ranging from 20 μm to 150 μm, the amount of heat transferred for system will increase, but decrease the pressure drop. However, for h v larger than 150 μm, the heat transfer and pressure drop both will reach a limit. A new family of geometrical dimensions of MCPL possessing an excellent heat flux of 178 W/cm 2 would be obtained. These findings will be useful in designing a better MCPL.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.