Radiotracers based on the peptide A20FMDV2 selectively target the cell surface receptor integrin αvβ6. This integrin has been identified as a prognostic indicator correlating with the severity of disease for several challenging malignancies. In previous studies of A20FMDV2 peptides labeled with 4-18F-fluorobenzoic acid (18F-FBA), we have shown that the introduction of poly(ethylene glycol) (PEG) improves pharmacokinetics, including increased uptake in αvβ6-expressing tumors. The present study evaluated the effect of site-specific C-terminal or dual (N- and C-terminal) PEGylation, yielding 18F-FBAA20FMDV2-PEG28 (4) and 18F-FBA-PEG28-A20FMDV2-PEG28 (5), on αvβ6-targeted tumor uptake and pharmacokinetics. The results are compared with 18F-FBA–labeled A20FMDV2 radiotracers (1–3) bearing either no PEG or different PEG units at the N terminus. Methods The radiotracers were prepared and radiolabeled on solid phase. Using 3 cell lines, DX3puroβ6 (αvβ6 +), DX3puro (αvβ6 −), and BxPC-3 (αvβ6 +), we evaluated the radiotracers in vitro (serum stability; cell binding and internalization) and in vivo in mouse models bearing paired DX3puroβ6–DX3puro and, for 5, BxPC-3 xenografts. Results The size and location of the PEG units significantly affected αvβ6 targeting and pharmacokinetics. Although the C-terminally PEGylated 4 showed some improvements over the un-PEGylated 18F-FBA-A20FMDV2 (1), it was the bi-terminally PEGylated 5 that displayed the more favorable combination of high αvβ6 affinity, selectivity, and pharmacokinetic profile. In vitro, 5 bound to αvβ6-expressing DX3puroβ6 and BxPC-3 cells with 60.5% ± 3.3% and 48.8% ± 8.3%, respectively, with a significant fraction of internalization (37.2% ± 4.0% and 37.6% ± 4.1% of total radioactivity, respectively). By comparison, in the DX3puro control 5 showed only 3.0% ± 0.5% binding and 0.9% ± 0.2% internalization. In vivo, 5 maintained high, αvβ6-directed binding in the paired DX3puroβ6– DX3puro model (1 h: DX3puroβ6, 2.3 ± 0.2 percentage injected dose per gram [%ID/g]; DX3puroβ6/DX3puro ratio, 6.5:1; 4 h: 10.7:1). In the pancreatic BxPC-3 model, uptake was 4.7 ± 0.9 %ID/g (1 h) despite small tumor sizes (20–80 mg). Conclusion The bi-PEGylated radiotracer 5 showed a greatly improved pharmacokinetic profile, beyond what was predicted from individual N- or C-terminal PEGylation. It appears that the 2 PEG units acted synergistically to result in an improved metabolic profile including high αvβ6 + tumor uptake and retention.
Abstract. We investigated consequences of priming East-West-German related self-knowledge for the strength of implicit, ingroup-directed positive evaluations among East- and West-Germans. Based on previous studies we predicted opposite effects of self-knowledge priming for East- and West-Germans. Since in general the East-German stereotype is regarded as more negative than the West-German one, bringing to mind East-West-related self-knowledge (relative to neutral priming) was expected to attenuate ingroup favoritism for East-Germans, but to increase it for West-Germans. After having fulfilled the priming tasks, participants worked on an IAT-version in which the to be classified stimuli were East- or West-German city names (dimension 1) and positive or negative adjectives (dimension 2). Results of Experiment 1 showed (a) that East- and West-German students implicitly evaluated their ingroups as more positive than the outgroups and (b) confirmedthe predictions of the priming influence. Experiment 2 replicated these findings with more representative samples from East- and West-Germany. The results are discussed with regard to underlying processes of implicit attitudes in intergroup contexts.
Purpose The integrin αvβ6 is overexpressed in a variety of aggressive cancers and serves as a prognosis marker. This study describes the conjugation, radiolabeling, and in vitro and in vivo evaluation of four chelators to determine the best candidate for 64Cu radiolabeling of A20FMDV2, an αvβ6 targeting peptide. Procedures Four chelators were conjugated onto PEG28-A20FMDV2 (1): 11-carboxymethyl-1,4,8,11-tetraazabicyclo[6.6.2]hexadecane-4-methanephosphonic acid (CB-TE1A1P), 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA), and 4,4′-((3,6,10,13,16,19-hexazazbicyclo[6.6.6]ico-sane-1,8-diylbis(aza-nediyl)) bis(methylene)dibenzoic acid (BaBaSar). All peptides were radiolabeled with 64Cu in ammonium acetate buffer at pH 6 and formulated to pH 7.2 in PBS for use. The radiotracers were evaluated using in vitro cell binding and internalization assays and serum stability assays. In vivo studies conducted include blocking, biodistribution, and small animal PET imaging. Autoradiography and histology were also conducted. Results All radiotracers were radiolabeled in good radiochemical purity (>95 %) under mild conditions (37–50 °C for 15 min) with high specific activity (0.58–0.60 Ci/µmol). All radiotracers demonstrated αvβ6-directed cell binding (>46 %) with similar internalization levels (>23 %). The radiotracers 64Cu-CB-TE1A1P-1 and 64Cu-BaBaSar-1 showed improved specificity for the αvβ6 positive tumor in vivo over 64Cu-DOTA-1 and 64Cu-NOTA-1 (+/− tumor uptake ratios—3.82 +/−0.44, 3.82±0.41, 2.58±0.58, and 1.29±0.14, respectively). Of the four radiotracers, 64Cu-NOTA-1 exhibited the highest liver uptake (10.83±0.1 % ID/g at 4 h). Conclusions We have successfully conjugated, radiolabeled, and assessed the four chelates CB-TE1A1P, DOTA, NOTA, and BaBaSar both in vitro and in vivo. However, the data suggests no clear “best candidate” for the 64Cu-radiolabeling of A20FMDV2, but instead a trade-off between the different properties (e.g., stability, selectivity, pharmacokinetics, etc.) with no obvious effects of the individual chelators.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.