Experience from a single group of operators demonstrates that carotid stenting can be performed with an acceptable 30-day complication rate. Late follow-up also demonstrates a low rate of fatal and nonfatal stroke. These results suggest that carotid stenting may be comparable to carotid endarterectomy, and it underscores the clinical equipoise and premise for the National Institute of Health-supported, randomized Carotid Revascularization Endarterectomy Versus Stent Trial comparing carotid stenting with carotid endarterectomy.
Background-The distal-balloon protection system is being evaluated for its efficacy in preventing embolic neurological events during carotid stenting (CAS). We sought to determine the effect of this system on the frequency of Doppler-detected microembolic signals (MES) during CAS. Methods and Results-Using transcranial Doppler, we compared the frequency of MES during CAS in 2 groups: 39 patients without distal protection and 37 who used the distal-balloon protection system (GuardWire). There were no significant differences in the clinical or angiographic characteristics between the 2 groups. Three phases with increased MES counts were identified during unprotected CAS; these were stent deployment, predilation, and postdilation (75Ϯ57, 32Ϯ36, and 27Ϯ25 METS, respectively). The distal-balloon protection significantly reduced the frequency of MES during CAS (MES counts: 164Ϯ108 in the control versus 68Ϯ83 in the protection group; Pϭ0.002), particularly during these 3 phases. MES in the protection group were detected predominantly during sheath placement, guidewire manipulation, and distal-balloon deflation. Conclusion-Three phases with increased MES counts were identified during unprotected CAS (eg, stent deployment, predilation, and postdilation). The distal-balloon protection system significantly reduced the frequency of MES during CAS, particularly during these 3 phases.
Carotid artery stenting with filter protection is technically feasible and safe. Early clinical outcomes appear to be favorable and need to be confirmed in a larger comparative study.
Carotid artery stenting can be performed in patients with restenosis following carotid endarterectomy with 30-day complication rates comparable to those of most published studies on repeat carotid endarterectomy. Results of late follow-up suggest that this technique is durable and efficacious.
Vertebral artery stent placement is feasible in patients who have significant VA stenosis, with predictably good angiographically demonstrated and clinical results. The 6-month angiographically confirmed restenosis rate appears to be low, as does the clinical recurrence rate. This technique solves the problems of elastic recoil and the treatment of angioplasty-induced dissections. Further prospective comparison with medical preventive strategies is warranted.
A 61-year-old man underwent carotid stenting with the distal-balloon protection system for symptomatic carotid artery stenosis. During the procedure, progressive elevation of the systolic blood pressure occurred, reaching a peak of 220 mm Hg immediately following deflation of the distal balloon. This was associated with severe headaches and progressive deterioration in the mental status to a coma. Head CT scan showed massive subarachnoidal hemorrhage contralateral to the stented side and a secondary intracerebral hemorrhage. Despite immediate successful blood pressure control, his condition deteriorated and he died 2 days later.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.