The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology present a list of key performance measures for endoscopy services. We recommend that these performance measures be adopted by all endoscopy services across Europe. The measures include those related to the leadership, organization, and delivery of the service, as well as those associated with the patient journey. Each measure includes a recommendation for a minimum and target standard for endoscopy services to achieve. We recommend that all stakeholders in endoscopy take note of these ESGE endoscopy services performance measures to accelerate their adoption and implementation. Stakeholders include patients and their advocacy groups; service leaders; staff, including endoscopists; professional societies; payers; and regulators.
BackgroundUsing standard diagnostic algorithms it is not always possible to establish the correct phenotype of inflammatory bowel disease which is essential for therapeutical decisions. Endoscopic ultrasound elastography is a new endoscopic procedure which can differentiate the stiffness of normal and pathological tissue by ultrasound. Therefore, we aimed to investigate the role of transrectal ultrasound elastography in distiction between Crohn's disease and ulcerative colitis.MethodsA total 30 Crohn's disease, 25 ulcerative colitis, and 28 non-inflammatory bowel disease controls were included. Transrectal ultrasound elastography was performed in all patients and controls. In all ulcerative coltis patients and 80% of Crohn's disease patients endoscopy was performed to assess disease activity in the rectum.ResultsSignificant difference in rectal wall thickness and strain ratio was detected between patients with Crohn's disease and controls (p = 0.0001). CD patients with active disease had higher strain ratio than patients in remission (p = 0.02). In ulcerative colitis group a significant difference in rectal wall thickness was found between controls and patients with active disease (p = 0.03). A significant difference in rectal wall thickness (p = 0.02) and strain ratio (p = 0.0001) was detected between Crohn's disease and ulcerative colitis patient group. Crohn's disease patients with active disease had a significantly higher strain ratio compared to ulcerative colitis patients with active disease (p = 0.0001).ConclusionTransrectal ultrasound elastography seems to be a promising new diagnostic tool in the field of inflammatory bowel disease. Further study on a larger cohort of patients is needed to definitely assess the role of transrectal ultrasound elastography in inflammatory bowel disease.
Our results showed that propofol provided good sedation with excellent pain control, a short recovery time and no significant hemodynamic side effects if carefully titrated. All the patients (and especially ASA III group) require monitoring and care of an anesthesiologist.
Background Training in advanced endoscopic techniques such as endoscopic retrograde cholangiopancreatography (ERCP) should be driven by key performance measures and standardized competence assessment in order to provide safe and high-quality interventions. We aimed to determine whether the involvement of trainees influences the outcome of the procedure and the incidence of ERCP-related adverse events. Methods This was an international, multicenter, prospective, observational study conducted at six high- and low-volume centers across Europe between October 2016 and October 2018, and included independent operators and their trainees. Standard report forms documenting indication, trainee involvement, technical outcome, and complications over a 30-day follow-up of consecutive ERCP procedures were included in the analysis. Technical success of the procedure and procedure-related adverse events were compared between procedures in the trainee group and the control group using bivariable and multivariable analysis. Results 21 trainees and 16 control endoscopists performed 1843 ERCPs during the study period. Trainee involvement in ERCP procedures did not decrease technical success (92.4 % vs. 93.7 %; P = 0.30) or increase the risk of adverse events (14.7 % vs. 14.6 %; P > 0.99). Conversely, there were significantly more moderate or severe adverse events in the control group compared with the trainee group (6.2 % vs. 3.4 %, P = 0.01). On multivariable analysis, only increased bilirubin levels, time to cannulation, and procedure difficulty level increased the risk of any procedure-related adverse event. Conclusion Trainee involvement in ERCP interventions within a proper teaching setting is safe and does not compromise the success of the procedure.
Our results showed that propofol provided good sedation with excellent pain control, a short recovery time and no significant haemodynamic side effects.
BackgroundColonic lipomas (CL) are rare benign adipose tumours usually found incidentally during colonoscopy. Endoscopic resection of symptomatic large CL remains controversial, since significant rates of perforation have been reported. In recent years, a novel technique for removal of large CL has been described, consisting of looping and ligating the lipoma with a nylon snare. The aim of our study was to evaluate the safety and efficacy of the “loop and let go” technique for large colon lipomas in a large case series.MethodsConsecutive patients referred to our institution for colonoscopy were eligible for the study. The diagnosis of CL was confirmed endoscopically by “pillow” and “naked fat” signs. Following diagnosis, lipomas were looped and ligated by endoloop. Follow-up colonoscopies were scheduled at 1- and 3-months interval.ResultsA total of 11 patients with large CL were enrolled in study. The indications for the colonoscopy included altered bowel habits (7 patients, 64%), screening for colorectal neoplasm (3 pts, 27%) and lower gastrointestinal bleeding (1 pts, 9%). The median lesion size was 3 cm (range 2,5-6 cm). Lesions were located at the hepatic flexure in 4 patients (36%), cecum and ascending colon (4 pts, 36%), rectosigmoid (2 pts, 18%) and transverse colon (1 pts, 9%). There were no immediate and late complications. On follow-up (median follow-up time 11,9 months, range 8–24), there was one small residual lipoma (<1 cm).ConclusionThe results of this study confirm that “loop-and-let-go” technique is safe and efficacious treatment of large colonic lipomas.
Introduction: The development of a fistula and/or an abscess are major complications in patients with Crohn’s disease. An abscess can involve any of the major viscera, including the liver and spleen. Case Report: A 27-year-old male patient with a 6-month history of NOD2/CARD15-positive Crohn’s disease with stenosis of the terminal ileum, previously treated with corticosteroids, was admitted with fever, chills, diarrhea, fatigue and cachexia. Diagnostic work-up revealed sepsis, an abscess in the right hepatic lobe, multiple abdominal collections and right-sided pleural effusion. It was felt that his poor general condition prevented surgical intervention and complex conservative treatment was initiated. It consisted of total parenteral nutrition, antibiotics, percutaneous drainage of the liver abscess, and thoracocentesis. Pus and blood cultures showed Lactobacillus acidophilus. There was a gradual improvement in the patient’s condition and the liver abscess decreased in diameter from 14 to 2 cm. Aminosalicylates and enteral nutrition were gradually introduced. The patient was discharged after 9 weeks in good general condition. Conclusion: Although extremely rarely, L. acidophilus can cause hepatic abscess and sepsis. This can be explained by immunologic incompetence due to corticosteroid treatment of Crohn’s disease.
The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology present a list of key performance measures for endoscopy services. We recommend that these performance measures be adopted by all endoscopy services across Europe. The measures include those related to the leadership, organization, and delivery of the service, as well as those associated with the patient journey. Each measure includes a recommendation for a minimum and target standard for endoscopy services to achieve. We recommend that all stakeholders in endoscopy take note of these ESGE endoscopy services performance measures to accelerate their adoption and implementation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.