This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.
In clinical photon beams, the dose outside the geometrical field limits is produced by photons originating from (i) head leakage, (ii) scattering at the beam collimators and the flattening filter (head scatter) and (iii) scattering from the directly irradiated region of the patient or phantom (internal scatter). While the first two components can be modified, e.g. by reinforcement of shielding components or by re-modeling the filter system, internal scatter remains an unavoidable contributor to the peripheral dose. Its relative magnitude compared to the other components, its numerical variation with beam energy, field size and off-axis distance as well as its spectral distribution are evaluated in this study. We applied a detailed Monte Carlo (MC) model of our 6/15 MV Siemens Primus linear accelerator beam head, provided with ideal head leakage shielding conditions (multi-leaf collimator without gaps) to assess the head scatter contribution. Experimental values obtained under real shielding conditions were used to evaluate the head leakage contribution. It was found that the MC-computed internal scatter doses agree with the results of our previous measurements, that internal scatter is the major contributor to the peripheral dose in the near periphery while head leakage prevails in the far periphery, and that the lateral decline of the internal scatter dose can be represented by the sum of two exponentials, with an asymptotic tenth value of 18 to 19 cm. Internal scatter peripheral doses from various elementary beams are additive, so that their sum increases approximately in proportion with field size. The ratio between normalized internal scatter doses at 6 and 15 MV is approximately 2:1. The energy fluence spectra of the internal scatter component at all points of interest outside the field have peaks near 500 keV. The fact that the energy-shifted internal scatter constitutes the major contributor to the dose in the near periphery has a general bearing for dosimetry, i.e. for energy-dependent detector responses and dose conversion factors, for the relative biological effectiveness and for second primary malignancy risk estimates in the peripheral region.
The OD1500 array's dosimetric properties showed the applicability of the array for clinical dosimetry with the possibility to increase the spatial sampling frequency and the coverage of a dose distribution with the sensitive areas of ionization chambers by merging two measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.