The i-gel, a novel supraglottic airway, has been proposed for use during cardiopulmonary resuscitation. We evaluated the performance of this device in manikins and anaesthetised patients when used by novices: medical students, non-anaesthetist physicians and allied health professionals all unfamiliar with the i-gel. Fifty i-gels were placed in manikins. Eighty-eight percent (44 ⁄ 50) were placed on the first attempt with a median insertion time of 14 s (range 7-45). I-gels were placed in 40 healthy anaesthetised patients. Success on the first attempt was 82.5% (33 ⁄ 40) and on the second attempt 15% (6 ⁄ 40). After three attempts there were no failures. Median insertion time was 17.5 s (range 7-197). Median airway seal was 20 cmH 2 O (range 13-40). One case of regurgitation and partial aspiration occurred. Our results suggest the i-gel is rapidly inserted in both manikins and patients by novice users and compares favourably to other supraglottic airways available. Further work determining safety and efficacy during cardiopulmonary resuscitation is required.
As the number of women giving birth by caesarean increases throughout most of the developed world, so too is research into postoperative pain relief for these women. Like most other post-surgical populations, the new mother needs effective pain relief so that she can mobilise early but she also has the added responsibility of needing to care for her newborn baby. There is no 'gold standard' for post-caesarean pain management; the number of options is large and the choice of method is at least partly determined by drug availability, regional and individual preferences, resource limitations and financial considerations. Most methods rely on opioids, supplemented with anti-inflammatory analgesics, nerve blocks or other adjunctive techniques. The aim of this review is to detail commonly used opioid-based methods and to review the evidence supporting non-opioid methods, when incorporated into a multimodal approach to post-caesarean pain management. Areas of promising research are also discussed.
Prophylactic vasopressor administration is commonly recommended to reduce maternal hypotension during spinal anaesthesia for caesarean section. Metaraminol has undergone limited investigation in obstetric anaesthesia for this purpose, particularly in comparison with phenylephrine. In this multicentre, randomised, double-blind, non-inferiority study, we compared prophylactic phenylephrine or metaraminol infusions, started immediately after spinal anaesthesia, in 185 women who underwent elective caesarean section. Phenylephrine was initially infused at 50 μg.min , and metaraminol at 250 μg.min . The primary outcome was the difference in umbilical arterial pH between groups; secondary outcomes included other neonatal acid-base measures, and maternal haemodynamic changes. The mean (SD) umbilical arterial pH was 7.28 (0.06) in the phenylephrine group vs. 7.31 (0.04) in the metaraminol group (p = 0.0002). The estimated mean (95%CI) pH difference of 0.03 (0.01-0.04) was above the pre-determined lower boundary of clinical non-inferiority, and also met the criterion for superiority. Umbilical artery lactate concentration was 2.8 (1.2) mmol.l in the phenylephrine group vs. 2.3 (0.7) mmol.l in the metaraminol group (p = 0.0018). Apgar scores did not significantly differ between groups. There was a higher incidence of hypotension, defined as systolic arterial pressure < 90% baseline, in the phenylephrine group; there was a higher incidence of hypertension and severe hypertension (systolic arterial pressure > 110% and > 120% baseline, respectively) in the metaraminol group. There was no significant difference between groups in the incidence of nausea, vomiting or maternal bradycardia. We conclude that, when used as an infusion to prevent hypotension after spinal anaesthesia for elective caesarean section, metaraminol is at least non-inferior to phenylephrine with respect to neonatal acid-base outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.