Mouthguards are frequently used for protection purposes, particularly by athletes competing in contact sports. However, there is increasing evidence supporting their use for improving performance. Studies have focused their use in athletes who do not traditionally use mouthguards and who may be looking for a performance edge. The aim of the current study was to evaluate the influence of a custom-made mouthguard (Parabite Malpezzi, PM) on maximal and submaximal physiological parameters related to performance in road cycling. Ten well-trained amateur road cyclists (34 ± 6 years) performed an incremental cardiopulmonary exercise test to exhaustion on a frictional braked cycle ergometer. Work rate (WR), heart rate, oxygen consumption ((Equation is included in full-text article.)), carbon dioxide production, and ventilation at the lactate threshold, at the respiratory compensation point (RCP), and at maximal exercise (MAX) were determined in normal conditions (C) and wearing PM. Cycling economy was also evaluated by analyzing the slope of the (Equation is included in full-text article.)/WR (Δ(Equation is included in full-text article.)/ΔWR, in milliliters per watt per minute) relationship during the test. Wearing the PM compared with C resulted in significant increases in WR at RCP (281 ± 32 vs. 266 ± 19 W, p = 0.04) and at MAX (353 ± 44 vs. 339 ± 38 W, p = 0.004). The PM also resulted in an average 8% lower Δ(Equation is included in full-text article.)/ΔWR (9.5 ± 1.1 vs. 10.3 ± 1.1 ml·W·min, p = 0.06) but did not significantly modify any of the other measured parameters at LT, RCP and MAX. To the best of our knowledge, this study is the first to evaluate the effects of a dentistry-designed mouthguard on physical performance of road cyclists. These results provide support for cyclists to correct jaw posture that may improve their exercise performance.
Hypereosinophilic syndrome was diagnosed in a 14 year old girl who presented with recurrent syncope. An ambulatory electrocardiogram revealed intermittent type 2 second degree left atrioventricular (AV) block. Focal thinning of the interventricular septum was noted on echocardiography, contrary to the commoner finding of regional ventricular wall thickening among patients with hypereosinophilic syndrome. High grade AV block as a manifestation of hypereosinophilic syndrome is rare and focal thinning of the left ventricle as a manifestation of the syndrome has not been described earlier.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.