Background: The failing Fontan circulation is associated with hepatic impairment. The nature of this liver injury is poorly defined. Objective: To establish the gross and histological liver changes of patients with Fontan circulation relative to clinical, biochemical and haemodynamic findings. Results: Zonal enhancement of the liver (4/12) on CT was more common in patients with lower hepatic vein pressures (p = 0.007), and in those with absent cardiac cirrhosis on histological examination (p = 0.033). Gastro-oesophageal varices (4/12) were more common in patients with higher hepatic vein pressure (21 (6.3) vs 12.2 (2.2) mm Hg, p = 0.013) and associated with more advanced cirrhosis (p = 0.037). The extent of cirrhosis (7/12) was positively correlated with the hepatic vein pressure (r = 0.83, p = 0.003). A significant positive correlation was found between the Fontan duration and the degree of hepatic fibrosis (r = 0.75, p = 0.013), as well as presence of broad scars (r = 0.71, p = 0.021). Protein-losing enteropathy (5/12) occurred more frequently in patients with longer Fontan duration (11.7 (3.2) vs 17.9 (6.1) years, p = 0.038). Conclusions: Liver injury, which can be extensive in this patient group, is related to Fontan duration and hepatic vein pressures. CT scan assists non-invasive assessment. Cardiac cirrhosis with the risk of developing gastro-oesophageal varices and regenerative liver nodules, a precursor to hepatocellular carcinoma, is common in this patient group.
Long term follow up studies have shown that transcatheter closure of perimembranous Ventricular Septal Defect (PmVSD) can be done safely and successfully. One of the most serious complications of VSD device closure is complete atrioventricular block which has been reported in 3-18% is various studies following VSD device closure. Amplatzar Duct Occluder II (ADO-II) device is now commonly being used for closure of small to moderate sized PmVSD. Complete heart block has not been reported with ADO-II device. We are reporting 2 cases of complete heart block following transcatheter closure of PmVSD using ADO-II device where sinus rhythm was established following early surgical removal of the device.
We recommend trans-thoracic real time three-dimensional echocardiography for the assessment of the congenitally malformed aortic valve, particularly to identify sites of fusion between leaflets and to measure the orificial diameter. The definition of nodularity, and the prognosis of nodules based on the mode of intervention, will need a comparative study of patients submitted to balloon dilation as well as those undergoing surgical valvotomy.
Achieving controlled flow between the systemic and pulmonary venous circulations is desirable in many complex congenital heart diseases. This includes the Fontan circulation, primary pulmonary hypertension, double inlet ventricles, or hypoplastic left heart with obstruction to the atrioventricular valve. As no specific device is available for this purpose, we developed a balloon-mounted stent technique to achieve a predetermined-sized fenestration of an atrial baffle in a patient with Fontan circulation. The details of the technique are described.
The objective of this study was to evaluate the effectiveness and safety of esmolol-induced negative ino- and chronotropism during stent/balloon angioplasty for aortic coarctation. Balloon angioplasty and stent placement have become widely accepted therapies for native and recurrent coarctation of the aorta (CoA). Trauma to the vessel wall and stent migration related to forward displacement of the balloon and/or stent by cardiac output, are the most common complications. Controlling stroke volume and heart rate may assist in balloon stability and accurate deployment of stents. All methods currently used to achieve this have significant limitations. We describe our experience using esmolol to control stroke volume and heart rate during balloon/stent angioplasty of CoA. We performed a retrospective review of all patients who had intravenous esmolol during percutaneous treatment of CoA. Six interventions were performed in six patients: coarctation stent angioplasty in five patients (two native coarctation) and balloon angioplasty alone in one patient. The median systolic blood pressure achieved during the procedure was 65 mmHg (range, 57-75) representing a median reduction of 40 mmHg (range, 20-80; p = 0.008) from baseline. The median heart achieved was 50 beats/min (range, 20-80), representing a median reduction of 20 beats/min (range, 15-90, p = 0.048) from baseline. Optimal stent position was obtained in all patients. Intravenous esmolol controls periprocedural hemodynamics effectively and safely during percutaneous therapy for aortic coarctation, thereby aiding accurate stent placement. Further evaluation of its use during other percutaneous left heart interventions is required.
Delineation of arch abnormalities is difficult by conventional 2-D echocardiography and MRI has been the investigation of choice. 3-D echocardiography is increasingly used in congenital heart disease for both functional anatomy and morphology. This case report demonstrates that 3-D echocardiography can be used in delineating arch anomalies, which can avoid further imaging that needs a general anaesthetic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.