The purpose of this study was to investigate the effects of pupil dilation on the parameters of the AL-Scan (Nidek Co., Ltd, Gamagori, Japan). We compared the measurements of axial length (AL), anterior chamber depth (ACD), central corneal keratometry reading, pupil diameter, and intraocular lens (IOL) power of 72 eyes of 72 healthy volunteers and patients scheduled for cataract surgery before and 45 min after instillation of cyclopentolate hydrochloride 1 % using the AL-Scan. Intraobserver repeatability was assessed by taking three consecutive recordings of ACD and AL. Only ACD readings were significantly different between predilation and postdilation (P < 0.001). The difference of the other measurements between two sessions was not statistically significant (P > 0.001). Only two cases in the study demonstrated changes in IOL power higher than 0.5 D. The intraobserver repeatability of both devices was good (CV values for ACD and AL were 0.16 and 0.20 %, respectively). Dilated pupil size did not affect the measurement of IOL power using the A-Scan optical biometer, but increase in ACD after dilation should be taken into account when performing refractive surgeries in which ACD is very important such as phakic anterior chamber IOL implantation.
Purpose: To report and compare the surgical, visual, and anatomical outcomes following treatment of dislocated intraocular lenses (IOLs). Methods: The medical records of 28 eyes of 28 patients were evaluated. Age, gender, pre-and postoperative best-corrected visual acuity (BCVA), surgical methods, and complications were recorded. Results: Pre-and postoperative BCVA ranged from counting fingers to 20/32 and from counting fingers to 20/25, respectively. Late-onset dislocations were the most frequently observed complication. The most frequent surgical method was IOL repositioning in 15 of 28 patients, followed by IOL exchange in 11 patients, and IOL removal in 2 patients. Only 1 patient required surgical re-intervention with IOL capture. Conclusions: Visual acuity improved following the use of either IOL repositioning or IOL exchange. No superiority of one method over the other was observed.In the present retrospective case series, management of dislocated IOLs with repositioning or exchange of the primary implant conferred comparable surgical and visual outcomes.
Keywords
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.