We present the clinical results and survivorship of consecutive 100 Birmingham Hip Resurfacings in 90 patients at a minimum follow-up of ten years. All procedures were carried out by an independent surgeon who commenced a prospective study in 1998. Patients were assessed clinically using the Western Ontario and McMaster Universities osteoarthritis index, Short-Form 36, Harris hip score and University of California, Los Angeles activity score. Radiological analysis was performed by an independent observer and blood metal ion levels concentrations were measured at ten years post-operatively in 62 patients. The median acetabular component inclination was 46.2° (34° to 59°) and anteversion 11.0° (0° to 30°). The median chromium concentration in the unilateral group was 1.74 (0.41 to 15.23) and for the bilateral group was 2.98 (1.57 to 18.01). The equivalent values for cobalt were 1.67 (0.54 to 20.4) and 1.88 (1.38 to 19.32). In total there were eight failures giving an overall survival at ten years of 92% (95% confidence interval (CI) 86.7 to 97.3). BHR in male patients had an improved survivorship of 94.6% (95% CI 89.4 to 100) compared with females at 84.6% (95% CI 70.7 to 98.5), but this did not reach statistical significance (p = 0.119). Four of the nine BHRs with a bearing diameter of 42 mm failed. The overall results were consistent with data produced from other centres in that the clinical outcome of large male patients was extremely encouraging, whereas the survival of the smaller joints was less satisfactory.
ine-wire external fixation is accepted as a minimally invasive technique, which can provide better outcomes than traditional open methods in the management of complex fractures of the tibial plateau. Available fixators vary in their biomechanical stability, and we believe that a stable beam-loading system is essential for consistently good outcomes. We assessed, prospectively, the clinical, radiological and general health status of 20 of 21 consecutive patients with complex fractures of the tibial plateau who had been treated using a standard protocol, with percutaneous screw fixation and a neutralisation concept with a fine wire beam-loading fixator allowing early weightbearing.Bony union was achieved in all patients, with 85% having good or excellent results. Full weight-bearing started during the first six weeks in 60% of patients. The general health status assessment correlated well with the knee scores and reflected a satisfactory outcome. [Br] 2003;85-B:691-9.
J Bone Joint Surg
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.