Micro milling process has become an attractive method for the rapid prototyping of micro devices. The process is based on subtractive manufacturing method in which materials from a sample are removed selectively. A comprehensive review on the fabrication of circular and rectangular cross-section channels of microfluidic devices using micro milling process is provided this review work. Process and machining parameters such as micro-tools selection, spindle speed, depth of cut, feed rate and strategy for process optimization will be reviewed. A case study on the rapid fabrication of a rectangular cross section channel of a microflow cytometer device with 200 um channel width and 50 um channel depth using CNC micro milling process is provided. The experimental work has produced a low surface roughness micro channel of 20 nm in roughness and demonstrated a microflow cytometer device that can produce hydrodynamic focusing with a focusing width of about 60 um.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.