18F-fluorination using aluminum-fluoride ([18F]AlF) chelate technique has been reported to give a low-to-moderate radiochemical yield, between 5 and 20%. Therefore, the work described here outlines the optimum 18F-fluorination condition for the formation of [18F]AlF2+ and [18F]AlF-NOTA-NHS complex with the radiochemical yield (RCY) and purity (RCP) of more than 90% as a prerequisite step before proceeding with the radiopharmaceutical preparation using the [18F]AlF-bifunctional chelator technique. As well as being simple, the suggested method is practical and relevant for beginners interested in 18F-fluorination with [18F]AlF-chelate complex technique or also for a researcher who aims to proceed on an extensive scale.
Background:: Organic solvents play an indispensable role in most of the radiopharmaceutical production stages. It is almost impossible to remove them entirely in the final formulation of the product. Objective:: In this presented work, an analytical method by gas chromatography coupled with flame ionization detection (GC-FID) has been developed to determine organic solvents in radiopharmaceutical samples. The effect of injection hold time, temperature variation in the injection port, and the column temperature on the analysis time and resolution (R ≥ 1.5) of ethanol and acetonitrile were studied extensively. Methods:: The experimental conditions were optimized with the aid of further statistical analysis; thence, the proposed method was validated following the International Council for Harmonisation (ICH) Q2 (R1) guideline. Results:: The proposed analytical method surpassed the acceptance criteria for the linearity > 0.990 (correlation coefficient of R2), precision < 2%, LOD, and LOQ, accuracy > 90% for all solvents. The separation between ethanol and acetonitrile was acceptable with a resolution, R > 1.5. Further statistical analysis of Oneway ANOVA revealed that the increment of injection holds time and variation of temperature at the injection port did not significantly affect the analysis time. Nevertheless, the variation of injection port temperature substantially influences the resolution of ethanol and acetonitrile peaks (p < 0.05). Conclusion:: The proposed analytical method has been successfully implemented to determine the organic solvent in the [18F]fluoro-ethyl-tyrosine ([18F]FET), [18F]fluoromisonidazole ([18F]FMISO), and [18F]fluorothymidine ([18F]FLT).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.