Study Objectives: The objectives were to develop and validate an algorithm for editing WatchPAT scoring and assess the accuracy in an unselected clinical population as well as age and sex substrata. Methods: Two hundred sixty-two participants were enrolled to undergo WatchPATsimultaneously with in-lab polysomnography (PSG) recordings for developing (n = 30), optimizing (n = 62), and validating (n = 170) an algorithm to review and edit respiratory events and sleep architecture of WatchPAT recordings, which was based on visual inspection of WatchPAT signals. Apnea-hypopnea index (AHI) and sleep indices were compared with PSG-derived and automated WatchPAT indices. Results: Although estimation of total sleep time (TST) was comparable between automated and manual algorithm, estimation of rapid eye movement (REM) sleep time was markedly improved with manual editing from 0.48, 23.0 min (−43.9 to 89.8) to 0.64, 18.3 min (−32.6 to 69.1) (correlation with PSG, mean difference [reference range] from PSG, respectively). Manual scoring also improved correlation and agreement with PSG AHI from 0.65, 2.5 events/h (−24.0 to 28.9) to 0.81, −4.5 events/h (−22.5 to 13.6) as well as concordance for categorical agreement of sleep-disordered breathing severity and concordance for detecting severe REM-related sleep-disordered breathing. Interscorer reliabilities were excellent for TST and AHI, while good for REM sleep time. The automated algorithm performed better in younger than in older patients, while performed similarly between men and women with respect to concordance statistics. The manual algorithm markedly improved concordances more in older patients and women than in their counterparts. Conclusions: Our manual editing algorithm improves correlation and agreement with PSG-derived sleep and breathing indices. Sex and age influence the accuracy of automated analysis and the performance of manual editing on AHI concordance.
Snoring is a highly prevalent condition associated with obstructive sleep apnea (OSA) and sleep disturbance in bed partners. Objective measurements of snoring in the community, however, are limited. The present study was designed to measure sound levels produced by self-reported habitual snorers in a single night. Snorers were excluded if they reported nocturnal gasping or had severe obesity (BMI > 35 kg/m2). Sound was measured by a monitor mounted 65 cm over the head of the bed on an overnight sleep study. Snoring was defined as sound ≥40 dB(A) during flow limited inspirations. The apnea hypopnea index (AHI) and breath-by-breath peak decibel levels were measured. Snore breaths were tallied to determine the frequency and intensity of snoring. Regression models were used to determine the relationship between objective measures of snoring and OSA (AHI ≥ 5 events/h). The area under the curve (AUC) for the receiver operating characteristic (ROC) was used to predict OSA. Snoring intensity exceeded 45 dB(A) in 66% of the 162 participants studied, with 14% surpassing the 53 dB(A) threshold for noise pollution. Snoring intensity and frequency were independent predictors of OSA. AUCs for snoring intensity and frequency were 77% and 81%, respectively, and increased to 87% and 89%, respectively, with the addition of age and sex as predictors. Snoring represents a source of noise pollution in the bedroom and constitutes an important target for mitigating sound and its adverse effects on bed partners. Precise breath-by-breath identification and quantification of snoring also offers a way to risk stratify otherwise healthy snorers for OSA.
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. AbstractBackground: A high prevalence of sleep disordered breathing (SDB) has been reported in persons with Marfan syndrome (MFS), a single gene disorder of connective tissue resulting in premature death from aortic rupture. The burden of SDB and accompanying hemodynamic stress could warrant broad screening in this population.Our goal was to assess the utility of traditional SDB screening tools in our sample of persons with MFS. Methods: Participants were recruited during an annual Marfan Foundation meeting and Marfan status confirmed using the Ghent criteria. Screening questionnaires were administered and SDB assessed by home sleep testing. We assessed accuracy of screening tools using receiver-operating characteristic curve analyses. Results: The prevalence of moderate-severe SDB was 32% in our sample of 31 MFS participants. The Stop-Bang questionnaire had the highest positive predictive value (PPV) of 60% and the highest negative predictive value (NPV) of 100% using the high-and moderate-risk cut-offs, respectively, and the Berlin questionnaire had a PPV of 50% and an NPV of 92.3% at the high-risk cut-off. When those with mild SDB were included, the Stop-Bang and the Sleep Apnea Clinical Score (SACS) questionnaires demonstrated useful screening accuracies with PPVs of 94.7% and 92.9%, and NPVs of 63.6% and 47.1%, respectively, at the moderate-risk cut-offs. Conclusion: A survey of SDB in a sample of persons with MFS reveals not only a high burden of SDB but also that conventional screening instruments have utility if adapted appropriately. Future studies should validate the utility of these screening tools given concerns that SDB may contribute to progression of aortic pathology in MFS. K E Y W O R D Sconnective tissue disorder, screening accuracy, SDB, surveys 2 of 9 | SOWHO et al.
This study showed similar adherence to NI and CPAP over a short period of usage. A randomized clinical trial is now essential for determining the comparative effectiveness of NI therapy in relation to treatment with CPAP.
Dynamic heterogeneity in lung ventilation is an important measure of pulmonary function and may be characteristic of early pulmonary disease. While standard indices like spirometry, body plethysmography, and blood gases have been utilized to assess lung function, they do not provide adequate information on regional ventilatory distribution nor function assessments of ventilation during the respiratory cycle. Emerging technologies such as xenon CT, volumetric CT, functional MRI and X-ray velocimetry can assess regional ventilation using non-invasive radiographic methods that may complement current methods of assessing lung function. As a supplement to current modalities of pulmonary function assessment, functional lung imaging has the potential to identify respiratory disease phenotypes with distinct natural histories. Moreover, these novel technologies may offer an optimal strategy to evaluate the effectiveness of novel therapies and therapies targeting localized small airways disease in preclinical and clinical research. In this review, we aim to discuss the features of functional lung imaging, as well as its potential application and limitations to adoption in research.
BackgroundMarfan syndrome (MFS) is a connective tissue disorder characterised by complex aortic pathology and a high prevalence of obstructive sleep apnoea (OSA). OSA produces intrathoracic transmural stresses that may accelerate aortic injury. The current study was designed to examine the associations between OSA risk and markers of aortic enlargement in MFS.MethodConsecutive patients with MFS were recruited at Johns Hopkins if they completed a STOP-BANG survey. Composite survey scores were categorised into those with low OSA risk (STOP-BANG <3) and high OSA risk (STOP-BANG ≥3). Participants’ aortic data were collated to ascertain aortic root diameter, dilatation and prior aortic root replacement. Regression analyses were used to examine associations between OSA risk strata and these aortic parameters.ResultsOf the 89 participants studied, 28% had a high OSA risk and 32% had aortic grafts. Persons with high OSA risk had greater aortic root diameter (mm) (ß=4.13, SE=1.81, p=0.027) and aortic root dilatation (ß=2.80, SE=1.34, p=0.046) compared with those with low OSA risk . In addition, the odds of prior aortic root replacement was three times greater in those with high OSA risk compared with those with low OSA risk.ConclusionIn MFS, high OSA risk is associated with aortic enlargement and a threefold increased risk of having had prior aortic root replacement. These findings invite further exploration of the relationship between OSA and aortic disease in MFS, and studies to clarify whether targeted interventions for OSA might mitigate aortic disease progression in MFS.Registration numberIRB00157483.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.