Introduction:
Tunneled femoral vein hemodialysis catheters are used when all other options for permanent vascular access or jugular central vein catheter are exhausted. There is little published literature on the outcome and survival of tunneled femoral vein catheters.
Methods:
Using a retrospective database, we identified all tunneled femoral dialysis catheters placed in the Nephrology department of our institute over a one-and-half year period. The outcomes, complications, and patency of these procedures was retrospectively evaluated.
Results:
Out of total 21 patients, 14 were female and 7 males with a mean age of 45 (range 17–73 years) and about one-fourth had diabetes mellitus (26%). Right-sided femoral catheter insertion was performed in 18 patients (85.7%) and 3 patients underwent left-sided insertion. Technical success of placement was 100% with no immediate complications. Median follow up period was 24 days. Primary catheter patency at 30, 60, 90, and 180 days were 81, 29, 18, and 12.5%, respectively. Three patients (15.7%) developed catheter-related deep venous thrombosis. Three catheters (14.2%) were removed for catheter-related infection and seven (33.3%) were removed because of absent blood flow.
Conclusion:
Our experience with tunneled femoral catheters revealed low catheter survival and significant complications (deep venous thrombosis and malfunction/occlusion).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.