Background:
Measurement of fractional flow reserve (FFR) has an established role in guiding percutaneous coronary intervention. We tested the hypothesis that, at the stage of diagnostic invasive coronary angiography, systematic FFR-guided assessment of coronary artery disease would be superior, in terms of resource use and quality of life, to assessment by angiography alone.
Methods:
We performed an open-label, randomized, controlled trial in 17 UK centers, recruiting 1100 patients undergoing invasive coronary angiography for the investigation of stable angina or non–ST-segment–elevation myocardial infarction. Patients were randomized to either angiography alone (angiography) or angiography with systematic pressure wire assessment of all epicardial vessels >2.25 mm in diameter (angiography+FFR). The coprimary outcomes assessed at 1 year were National Health Service hospital costs and quality of life. Prespecified secondary outcomes included clinical events.
Results:
In the angiography+FFR arm, the median number of vessels examined was 4 (interquartile range, 3–5). The median hospital costs were similar: angiography, £4136 (interquartile range, £2613–£7015); and angiography+FFR, £4510 (£2721–£7415;
P
=0.137). There was no difference in median quality of life using the visual analog scale of the EuroQol EQ-5D-5L: angiography, 75 (interquartile range, 60–87); and angiography+FFR, 75 (interquartile range, 60–90;
P
=0.88). The number of clinical events was as follows: deaths, 5 versus 8; strokes, 3 versus 4; myocardial infarctions, 23 versus 22; and unplanned revascularizations, 26 versus 33, with a composite hierarchical event rate of 8.7% (48 of 552) for angiography versus 9.5% (52 of 548) for angiography+FFR (
P
=0.64).
Conclusions:
A strategy of systematic FFR assessment compared with angiography alone did not result in a significant reduction in cost or improvement in quality of life.
Registration:
URL:
https://www.clinicaltrials.gov
; Unique identifier: NCT01070771.
An atrial septal pouch (ASP) results from partial fusion of the septum primum and the septum secundum, and depending on the site of fusion, the pouch can be left-sided (LASP) or right-sided (RASP). LASPs have been described in association with thrombi found in patients admitted with acute strokes, raising awareness of its potential cardioembolic role, especially in those with no other clearly identifiable embolic source. We retrospectively studied 39 patients in whom the presence of an ASP had been identified by three-dimensional transesophageal echocardiography (3DTEE) and who had a two-dimensional transesophageal echocardiogram (2DTEE) performed during the same clinical encounter. The incremental value provided by 3DTEE over 2DTEE included the detection of six ASPs not found by 2DTEE; the detection of two ASPs in the same subject (in four patients) not identified by 2DTEE; larger ASP measurements of length and height in over 80% of the cases; and measurement of the ASP width (elevational axis) for the calculation of the area of the ASP opening, because of its unique capability to view the pouch en face. In addition, the volume of ASP and of the echogenic masses contained in the ASP (four of 39 patients) could be calculated by 3DTEE, which is a superior parameter of size characterization when compared to individual dimensions. One of these patients who presented with ischemic stroke diagnosed by magnetic resonance imaging had a large (>2 cm) mass in a LASP, with echolucencies similar to those seen in thrombi and associated with clot lysis and resolution. This mass completely disappeared on anticoagulant therapy lending credence that it was most likely a thrombus. There was no history of stroke or any other type of embolic event in the other three patients with masses in ASP. In conclusion, this retrospective study highlights the incremental value of 3DTEE over 2DTEE in the comprehensive assessment and characterization of ASPs, which can aid in the clarification of their role in cryptogenic stroke patients.
We describe a case of hypertrophic cardiomyopathy with mid-left ventricular obstruction and apical aneurysm containing thrombi where live/real time three-dimensional transthoracic echocardiography provided incremental value over two-dimensional echocardiography in assessing the findings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.