Abstract. The European APD Outcome Study (EAPOS) is a 2-yr, prospective, multicenter study of the feasibility and clinical outcomes of automated peritoneal dialysis (APD) in anuric patients. A total of 177 patients were enrolled with a median age of 54 yr (range, 21 to 91 yr). Previous median total time on dialysis was 38 mo (range, 1.6 to 259 mo), and 36% of patients had previously been on hemodialysis for Ͼ90 d. Diabetes and cardiovascular disease were present in 17% and 46% of patients, respectively. The APD prescription was adjusted at physician discretion to aim for creatinine clearance (Ccrea) Ն60 L/wk per 1.73 m 2 and ultrafiltration (UF) Ն750 ml/24 h during the first 6 mo. Baseline solute transport status (D/P) was determined by peritoneal equilibration test. At 1 yr, 78% and 74% achieved Ccrea and UF targets, respectively; median drained dialysate volume was 16.2 L/24 h with 50% of patients using icodextrin. Baseline D/P was not related to UF achieved at 1 yr. At 2 yr, patient survival was 78% and technique survival was 62%. Baseline predictors of poor survival were age (Ͼ65 yr; P ϭ 0.006), nutritional status (Subjective Global Assessment grade C; P ϭ 0.009), diabetic status (P ϭ 0.008), and UF (Ͻ750 ml/24 h; P ϭ 0.047). Time-averaged analyses showed that age, Subjective Global Assessment grade C and diabetic status predicted patient survival with UF the next most significant variable (risk ratio, 0.5/L per d; P ϭ 0.097). Baseline Ccrea, time-averaged Ccrea, and baseline D/P had no effect on patient or technique survival. This study shows that anuric patients can successfully use APD. Baseline UF, not Ccrea or membrane permeability, is associated with patient survival.
♦ Objective Conventional continuous ambulatory peritoneal dialysis (CAPD) in patients without residual renal function and with high solute transport is associated with worse clinical outcomes. Automated peritoneal dialysis (APD) has the potential to improve both solute clearance and ultrafiltration in these circumstances, but its efficacy as a treatment modality is unknown. The European Automated Peritoneal Dialysis Outcomes Study (EAPOS) is a 2-year, prospective, European multi-center study designed to determine APD feasibility and clinical outcomes in anuric patients. The present article describes the baseline data for patients recruited into the study. ♦ Design All PD patients treated in the participating centers were screened for inclusion criteria [urinary output < 100 mL/24 h, or residual renal function (RRF) < 1 mL/min, or both]. After enrollment, changes were made to the dialysis prescription to achieve a weekly creatinine clearance above 60 L per 1.73 m2 and an ultrafiltration rate above 750 mL in 24 hours. ♦ Setting The study is being conducted in 26 dialysis centers in 13 European countries. ♦ Baseline Data Collection The information collected includes patient demographics, dialysis prescription, achieved weekly creatinine clearance, and 24-hour ultra-filtration (UF). ♦ Results The study enrolled 177 anuric patients. Median dialysis duration before enrollment was 22.5 months (range: 0 – 285 months). Mean solute transport measured as the dialysate-to-plasma ratio of creatinine (D/PCr) was 0.74 ± 0.12. Patients received APD for a median of 9.0 hours overnight (range: 7 – 12 hours) using a median of 11.0 L of fluid (range: 6 – 28.75 L). Median daytime volume was 4.0 L (range: 0.0 – 9.0 L). Tidal dialysis was used in 26 patients, and icodextrin in 86 patients. At baseline, before treatment optimization, the weekly mean total creatinine clearance was 65.2 ± 14.4 L/1.73 m2, with 105 patients (60%) achieving the target of more than 60 L/1.73 m2. At baseline, 81% of patients with high transport, 69% with high-average transport, and 40% with low-average transport met the target. At baseline, 70% of patients with a body surface area (BSA) below 1.7 m2, 60% with a BSA of 1.7 – 2.0 m2, and 56% with a BSA above 2.0 m2 achieved 60 L/1.73 m2 weekly. Median UF was 1090 mL/24 h, and 75% of patients achieved the UF target of more than 750 mL/24 h. ♦ Conclusion This baseline analysis of anuric patients recruited into the EAPOS study demonstrates that a high proportion of anuric patients on APD can achieve dialysis and ultrafiltration targets using a variety of regimes. This 2-year follow-up study aims to optimize APD prescription to reach predefined clearance and ultrafiltration targets, and to observe the resulting clinical outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.