PurposeThe purpose of the study was to determine the accuracy of intraocular pressure (IOP) measurement after small incision lenticule extraction (SMILE) using Goldmann applanation tonometry (GAT) and ocular response analyzer (ORA).MethodsThis is a prospective clinical study that was conducted on 30 eyes in the interval between February 2016 and September 2016. The age of the patients ranged between 19 and 40 years. The patients underwent SMILE surgery using the femto laser. IOP was measured preoperatively and 1 month postoperatively by both techniques, the GAT and the ORA.ResultsGAT recorded lower values than ORA values (IOPcc) preoperatively and postoperatively and the difference was statistically significant. Both GAT and ORA IOP measurements decreased after SMILE. There was no statistically significant correlation between the changes in the GAT and ORA readings and the postoperative corneal pachymetry or the lenticule thickness. Both corneal hysteresis and corneal resistance factor showed significant decline after the procedure, which correlated with the lenticule thickness.ConclusionSMILE causes significant reduction in IOP measurement by ORA and GAT. Corneal biomechanics decreases following SMILE and this correlates with lenticule thickness.
SMILE is as safe and predictable as FS-LASIK. According to the ORA system, SMILE is not better than FS-LASIK in terms of biomechanical changes. However, SMILE causes less effect on dry eye parameters during the first 3 postoperative months.
PurposeThe purpose of this study is to compare the efficacy of intratunnel cross-linking combined with intrastromal corneal ring segment (ICRS) implantation versus combined epithelium-off (epi-off) cross-linking and ICRS implantation for the management of keratoconus.MethodsOur study included 20 eyes of 12 patients with moderate-to-severe keratoconus. Group A included 10 eyes that underwent simultaneous ICRS implantation with intratunnel cross-linking. Group B included 10 eyes that underwent simultaneous ICRS implantation with epi-off cross-linking. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest sphere and cylinder, mean and maximum keratometric readings, corneal thickness at pachy apex and thinnest location, as well as corneal hysteresis (CH) and corneal resistance factor (CRF) were compared preoperatively and at 6 months postoperatively.ResultsThe mean UDVA and CDVA improved significantly in both groups with a statistically nonsignificant difference between the groups (P=0.798 and 0.126, respectively). The manifest cylinder decreased significantly in both groups, while the manifest sphere decreased significantly in Group A but nonsignificantly in Group B with a statistically nonsignificant difference between the groups (P=0.773 and 0.111, respectively). Both techniques led to significant flattening of the cornea and a significant decrease of Km and Kmax with a statistically nonsignificant difference between the groups (P=0.312 and 0.857, respectively). There was a statistically significant decrease in CH in both groups postoperatively; however, there was a statistically nonsignificant increase in CRF after both techniques with a statistically nonsignificant difference between the groups in the mean change of CH and CRF (P=0.633 and 0.313, respectively). No intraoperative or postoperative complications were observed in both groups.ConclusionBoth techniques improved the visual and refractive outcomes in cases of moderate and severe keratoconus with no statistically significant difference between the groups; however, simultaneous intratunnel cross-linking and ICRS implantation showed early visual rehabilitation due to the absence of epithelial defect.
Purpose To evaluate femtosecond laser in DSAEK surgery as an improvement to manual DSAEK. Settings Department of Ophthalmology, Cairo University. Design A retrospective observational clinical study. Methods 20 eyes with SBK and Fuchs' dystrophy underwent a Femto-assisted DSAEK by laser cutting of two matching posterior stromal discs in the recipient and donor corneas and then fitting the donor disc in the posterior corneal defect of the recipient using Busin's glide or Terry forceps. Results Corneal thickness decreased significantly from a mean of 900-micron preoperative values (900.7 m) to 562 m postoperatively. Evidence of side healing was documented by OCT. One patient had a double AC, one patient had an air interface entrapment “Double Bubble,” one patient had a fungal infection and was treated by a therapeutic penetrating keratoplasty, and one patient had a CMO. Conclusion Femtolaser-assisted DSAEK may be superior to manual techniques as it offers better centration, thinner graft/host complex, earlier corneal detergecense, and stronger healing. This study was registered at Researchregistry.com with a UID: researchregistry2274.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.