Atrial fibrillation (AF) is the most common symptomatic and sustained cardiac arrhythmia. It affects approximately 2-3 million people in the USA alone with an increased incidence and prevalence worldwide. It is associated, in addition to worsening quality of life, with increased morbidity and mortality especially in poorly controlled AF, affecting mostly those older than 65 years of age. Radiofrequency ablation was found to be a good strategy for focal isolation of pulmonary veins triggering from the vulnerable atrial substrate but is a time-consuming procedure and carries the risk of multiple complications like tamponade which could be fatal, atrioesophageal fistula and local thrombus formation at the site of ablation. Cryoballoon ablation with pulmonary vein isolation has emerged in the past few years as a breakthrough novel technology for the treatment of drug-refractory AF. It is a relatively simple alternative for point-by-point radiofrequency ablation of paroxysmal AF and is associated with fewer incidences of fatal complications such as cardiac perforation. As experience with this new tool accumulates, the field faces new challenges in the form of rare compilations including gastroparesis, phrenic nerve palsy, atrioesophageal fistula, pulmonary vein stenosis, thromboembolism pericardial effusion, and tamponade.
Double-chambered right ventricle (DCRV) is a rare congenital heart disorder involving 2 different right ventricle (RV) pressure compartments that is often associated with ventricular septal defect (VSD). Usually, the obstruction is caused by an anomalous muscle bundle crossing the RV from the interventricular septum to the RV free wall. We are reporting a case of double-chambered right ventricle associated with ventricular septal defect and congenital absence of the pulmonary valve, a rare form of congenital infundibular pulmonary stenosis. In addition to ventricular septal defect, our patient had congenital absence of the pulmonary valve, which is very unusual and has never been reported to our knowledge.
As the number of patients having implantable cardioverter defibrillator (ICD) devices is increasing, it is important for the physicians and patients to be aware of situations and conditions that can result in interference with normal functioning of these devices. There are multiple cases of malfunction of ICDs reported in literature and it may be of great significance to have an overview of these incidents for appropriate recognition and future prevention. Here we are reviewing the available literature as well as reporting an interesting case of electromagnetic interference (EMI) resulting from leak of current in pool water causing firing of ICD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.