This review article discusses the most recent significant advances in the sample preparation and mass spectrometry aspects of high-throughput bioanalysis by LC/MS/MS for the quantitation of drugs, metabolites and endogenous biomolecules in biological matrices. The introduction and implementation of automated 96-well extraction has brought about high-throughput approaches to the biological sample preparation techniques of solid-phase extraction, liquid-liquid extraction and protein precipitation. The fast-flow on-line extraction technique is a different high-throughput approach that has also significantly speeded up analysis by LC/MS/MS. The use of pierceable caps for biological tubes further enhances the analysis speed and improves the safety in handling biological samples. The need for adequate chromatographic separation in order to eliminate interferences due to metabolites and/or matrix effects in LC/MS/MS is discussed. To highlight our limited understanding of atmospheric pressure ionization mass spectrometry, results from recent investigations that appear to be counter-intuitive are presented. Looking ahead to the future, multiplexed LC/MS/MS systems and capillary LC are presented as areas that can bring about further improvements in analysis speed and sensitivity to quantitative bioanalysis by LC/MS/MS.
Selective, accurate, and reproducible liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of mevalonic acid, an intermediate in the biosynthesis of cholesterol and therefore a useful biomarker in the development of cholesterol lowering drugs, in human plasma and urine. A hepta-deuterated analog of mevalonic acid was used as the internal standard. For both methods, calibration standards were prepared in water, instead of human plasma and urine, due to unacceptably high levels of endogenous mevalonic acid. The lower quality control (QC) samples were prepared in water while the higher QC samples were prepared in the biological matrices. For the isolation/purification of mevalonic acid from the plasma and urine matrices, the samples were first acidified to convert the acid analyte into its lactone form. For the plasma samples, the lactone analyte was retained on and then eluted off a polymeric solid-phase extraction (SPE) sorbent. For the urine method, the sample containing the lactone analyte was passed through a C-18 SPE column, which did not retain the analyte, with the subsequent analyte retention on and then elution off a polymeric SPE sorbent. Chromatographic separation was achieved isocratically on a polar-endcapped C-18 analytical column with a water/methanol mobile phase containing 0.5 mM formic acid. Detection was by negative-ion electrospray tandem mass spectrometry. The standard curve range was 0.500-20.0 ng/mL for the plasma method and 25.0-1,000 ng/mL for the urine method. Excellent accuracy and precision were obtained for both methods at all concentration levels tested. It was interesting to note that for certain batches of urine, when a larger sample volume was used for analysis, a high degree of matrix effect was observed which resulted not only in the attenuation of the absolute response, but also in a change of analyte/internal standard response ratio. This demonstrated that, under certain conditions, the use of a stable isotope analog internal standard does not, contrary to conventional thinking, guarantee the constancy of the analyte/internal response ratio, which is a prerequisite for a rugged bioanalytical method. On the other hand, under conditions where the sample matrix does not have such a deleterious effect, we have found that a stable isotope analog could serve as a surrogate (substitute) analyte. Thus, we have shown that using calibration standards prepared by spiking plasma with tri-deuterated or tetra-deuterated mevalonic acid, instead of mevalonic acid itself (the analyte), plasma QC samples that contain mevalonic acid can be successfully analyzed for the accurate and precise quantitation of mevalonic acid. The use of a surrogate analyte provides the opportunity to gauge the daily performance of the method for the low concentration levels prepared in the biological matrix, which otherwise is not achievable because of the endogenous concentrations of the analyte in the biological matrices.
Organic anion-transporting polypeptides (OATP) 1B1, 1B3, and 2B1 can serve as the loci of drug-drug interactions (DDIs). In the present work, the cynomolgus monkey was evaluated as a potential model for studying OATP-mediated DDIs. Three cynomolgus monkey OATPs (cOATPs), with a high degree of amino acid sequence identity (91.9, 93.5, and 96.6% for OATP1B1, 1B3, and 2B1, respectively) to their human counterparts, were cloned, expressed, and characterized. The cOATPs were stably transfected in human embryonic kidney cells and were functionally similar to the corresponding human OATPs (hOATPs), as evident from the similar uptake rate of typical substrates (estradiol-17b-D-glucuronide, cholecystokinin octapeptide, and estrone-3-sulfate). Moreover, six known hOATP inhibitors exhibited similar IC 50 values against cOATPs. To further evaluate the appropriateness of the cynomolgus monkey as a model, a known hOATP substrate [rosuvastatin (RSV)]-inhibitor [rifampicin (RIF)] pair was examined in vitro; the monkey-derived parameters (RSV K m and RIF IC 50 ) were similar (within 3.5-fold) to those obtained with hOATPs and human primary hepatocytes. In vivo, the area under the plasma concentration-time curve of RSV (3 mg/kg, oral) given 1 hour after a single RIF dose (15 mg/kg, oral) was increased 2.9-fold in cynomolgus monkeys, consistent with the value (3.0-fold) reported in humans. A number of in vitro-in vivo extrapolation approaches, considering the fraction of the pathways affected and free versus total inhibitor concentrations, were also explored. It is concluded that the cynomolgus monkey has the potential to serve as a useful model for the assessment of OATP-mediated DDIs in a nonclinical setting. IntroductionDrug-drug interactions (DDIs) have often been attributed to cytochrome P450 (P450) enzymes because of their prominent role in the metabolic clearance of drugs (Vuppugalla et al., 2010). More recently, however, attention has turned to active transport processes in different organs and the close interplay between drug transport and metabolism at the cellular level. In particular, organic anion-transporting polypeptides (OATPs) are known to mediate the active uptake of numerous drugs into hepatocytes and hence govern their overall clearance, pharmacokinetic profile, and liver-toplasma ratio (Giacomini et al., 2010;Fenner et al., 2012;Yoshida et al., 2012).OATPs can also serve as the loci of important DDIs leading to changes in systemic and local drug concentrations, possibly resulting in altered efficacy and enhanced toxicity (Giacomini et al., 2010;Yoshida et al., 2012). For example, cyclosporine A (CsA) increases the area under the concentration-time curve (AUC) (∼15-fold) and C max (∼14-fold) of atorvastatin in s This article has supplemental material available at jpet.aspetjournals.org.ABBREVIATIONS: AUC, area under the concentration-time curve; CCK-8, cholecystokinin octapeptide; CI, confidence interval; cOATP, cynomolgus organic anion-transporting polypeptide; CsA, cyclosporine A; DDI, drug-drug inter...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.