Background
Although it is traditionally regarded as a single entity, perioperative stroke comprises 2 separate phenomena (early/intraoperative and delayed/postoperative stroke). We aimed to systematically evaluate incidence, risk factors, and clinical outcome of early and delayed stroke after cardiac surgery.
Methods and Results
A systematic review (
MEDLINE
,
EMBASE
, Cochrane Library) was performed to identify all articles reporting early (on awakening from anesthesia) and delayed (after normal awakening from anesthesia) stroke after cardiac surgery. End points were pooled event rates of stroke and operative mortality and incident rate of late mortality. Thirty‐six articles were included (174 969 patients). The pooled event rate for early stroke was 0.98% (95%
CI
0.79% to 1.23%) and was 0.93% for delayed stoke (95%
CI
0.77% to 1.11%;
P
=0.68). The pooled event rate of operative mortality was 28.8% (95%
CI
17.6% to 43.4%) for early and 17.9% (95%
CI
14.0% to 22.7%) for delayed stroke, compared with 2.4% (95%
CI
1.9% to 3.1%) for patients without stroke (
P
<0.001 for early versus delayed, and for perioperative stroke, early stroke, and delayed stroke versus no stroke). At a mean follow‐up of 8.25 years, the incident rate of late mortality was 11.7% (95%
CI
7.5% to 18.3%) for early and 9.4% (95%
CI
5.9% to 14.9%) for delayed stroke, compared with 3.4% (95%
CI
2.4% to 4.8%) in patients with no stroke. Meta‐regression demonstrated that off‐pump was inversely associated with early stroke (β=−0.009,
P
=0.01), whereas previous stroke (β=0.02,
P
<0.001) was associated with delayed stroke.
Conclusions
Early and delayed stroke after cardiac surgery have different risk factors and impacts on operative mortality as well as on long‐term survival.
Wellens syndrome is an electrocardiographic (ECG) pattern involving T waves in precordial leads that was first described in 1982 among a group of patients presenting with unstable angina suggestive of critical stenosis of the proximal left anterior descending (LAD) coronary. It is crucial for emergency physicians and internists to be able to recognize these patterns, as they occur in the symptom-free periods and represent a pre-infarction state that needs early intervention. Type A, which is characterized by biphasic T waves, mainly in V2 and V3, poses a significant challenge to recognize the pattern, and failure to do so can lead to devastating outcome. We report a case of type A Wellens syndrome with subtle T wave changes that went unnoticed during the initial assessment and led to start off on a wrong foot.
Loeffler endocarditis is a complication of hypereosinophilic syndrome resulting from eosinophilic infiltration of heart tissue. We report a case of Loeffler endocarditis in which three-dimensional transthoracic and transesophageal echocardiography provided additional information to what was found by two-dimensional transthoracic echocardiography alone. Our case illustrates the usefulness of combined two- and three-dimensional echocardiography in the assessment of Loeffler endocarditis. In addition, a summary of the features of hypereosinophilic syndrome and Loeffler endocarditis is provided in tabular form.
Ventricular septal rupture is a serious complication following acute myocardial infarctions and is associated with a significant mortality rate. Classically, two-dimensional transthoracic echocardiography has been used to diagnose this complication and visualize its location. Two-dimensional transesophageal echocardiography has supplemented the transthoracic approach by providing more accurate assessment of the defect size and in guiding closure both percutaneously and intraoperatively. This modality, however, is limited to two-dimensional views only, and a greater breadth of information is instead available through the use of three-dimensional transesophageal echocardiography. We present a series of 11 patients in which live/real time three-dimensional transesophageal echocardiography offered incremental benefits over two-dimensional imaging alone.
Both SVC and RAA could be imaged by 2DTTE and 3DTTE in 53% of 40 patients (two separate groups of 20 consecutive patients) studied demonstrating the technical feasibility of this approach. SVC size and collapsibility, CT and RAA size, and RAA fractional shortening were evaluated in both groups by both 2D and 3DTTE. 3DTTE provided incremental value over 2DTTE by its ability to view en face the SVC in short axis and the base of RAA and RAA volumes resulting in more comprehensive assessment of their size and function.
Background
Cardiac imaging is the cornerstone of the pretranscatheter aortic valve replacement (TAVR) assessment. Multi‐detector computed tomography (MDCT) is considered the conventional imaging modality. However, there is still no definitive gold standard. Targeted cohort of inoperable high‐risk patients with underlying comorbidities, particularly renal impairment, makes apparent the need for MDCT alternative. We aimed to demonstrate the correlation extent between MDCT and three‐dimensional transesophageal echocardiography (3DTEE) aortic annular area measures and to answer the question: Is 3DTEE a good alternative to MDCT?
Methods
A systematic literature search and meta‐analysis were conducted to evaluate the degree of correlation and agreement between 3DTEE and MDCT aortic annular sizing. A thorough assessment of EMBASE, PubMed, and Cochrane Central Register of Controlled Trials (CENTRAL) was performed. All studies comparing 3DTEE and MDCT in relation to aortic annular sizing were included.
Results
Thirteen studies were included (N = 1228 patients). A strong linear correlation was found between 3DTEE and MDCT measurements of aortic annulus area (r = 0.84, P < 0.001), mean perimeter (r = 0. 0.85, P < 0.001), and mean diameter (r = 0.80, P < 0.001). Bland–Altman plots revealed smaller mean 3DTEE values in comparison to MDCT for aortic annular area, the mean difference being −2.22 mm2 with 95% limits of agreement −12.79 to 8.36.
Conclusion
Aortic annulus measurements obtained by 3DTEE demonstrated a high level of correlation with those evaluated by MDCT. This makes 3DTEE a feasible choice for aortic annulus assessment, with advantage of real time assessment, lack of contrast, and no radiation exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.