Background. Long span is seen in many clinical situations. Treatmentplanning options of these cases are difficult and may require FPD, RPD or ISP. Each option has its own disadvantages, including mechanical problems, patient comfort and cost. This article will evaluate the stress distribution of a different treatment option, which consists of adding a single sup-porting implant to the FPD by using 3D finite element analysis.Methods. Three models, each consisting of 5 units, were created as follows: 1. Tooth Pontic Pontic Pontic Tooth; 2. Tooth Pontic Implant Pontic Tooth; 3. Tooth Pontic Pontic Implant Tooth. An axial force was applied to the prostheses by using 3D finite element method and stresses were evaluated.Results. The maximum stress was found in the prostheses in all the models; the highest stress values in all the shared components of the models were almost similar. Stress in implants was lower in the second model than the third one.Conclusion. Adding a supporting implant in long-span FPD has no advantages while it has the disadvantages of complicating treatment and the complications that may occur to the implant and surrounding bone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.