Study DesignRetrospective cohort study.PurposeComparison between three different minimally invasive surgical (MIS) fusion techniques for single-level lumbar spondylolisthesis.Overview of LiteratureThere has been an increase in the development and utilization of MIS techniques for lumbar spine fusion. No study has compared the efficacy of MIS-posterolateral fusion (MIS-PLF), MIS-transforaminal lumbar interbody fusion (MIS-TLIF), and midline lumbar fusion (MIDLF) with modified cortical bone trajectory screws for lumbar spondylolisthesis.MethodsFifty-nine patients with single-level lumbar spondylolisthesis and a minimum follow-up period of 1 year were included in this study. The MIS-PLF, MIS-TLIF, and MIDLF groups included 22, 15, and 22 patients, respectively. The average age of the groups was 70.6, 49.3, and 62.7 years, respectively. The evaluation parameters were operation time, intraoperative bleeding, serum C-reactive protein (CRP) value, creatine kinase (CK) value, and overall functional outcome as per the Japanese Orthopedic Association Back Pain Evaluation Questionnaire (JOABPEQ) score. The changes in the lumbar lordosis angle (LLA), segmental disc angle (SDA), and disc height were measured. Fusion rate, screw loosening, and loss of correction were also assessed.ResultsMIDLF showed a significantly shorter operation time (111 min), less bleeding amount (112.5 mL), and lower values of CRP and CK than the other two techniques. There was no significant difference in the JOABPEQ scores of the three groups. MIDLF resulted in a greater increase in the LLA and SDA postoperatively. MIDLF and MIS-TLIF resulted in a significant increase in the middle disc height compared with MIS-PLF. MIDLF showed a lower loss of correction after 6 months postoperatively (2.6%) than MIS-PLF (5.2%) and MIS-TLIF (4.2%). The fusion rate was 100% in the MIDLF and MIS-TLIF groups and 90% in the MIS-PLF group. Screw loosening occurred in 10% of the MIS-PLF cases, 7.14% of the MIS-TLIF cases, and 4.76% of the MIDLF cases.ConclusionsMIDLF was the least invasive, and there was no significant difference between the three groups in terms of fusion, screw loosening, and clinical outcomes.
Introduction: Transforaminal lumbar interbody fusion (TLIF) is used to reconstruct disc height and reduce degenerative deformity in spinal fusion. Patients with osteoporosis are at high risk of TLIF cage subsidence; possibly due to the relatively small footprint compared to anterior interbody devices. Recently, modular TLIF cage with an integral rail and slot system was developed to reduce cage subsidence and allow early rehabilitation.Objective: To study the safety of a modular TLIF device in patients with degenerative disc disorders (DDD) with regard to surgical complications, non-union, and subsidence.Methods: Patients with DDD treated with a modular TLIF cage (Polyetheretherketone (PEEK), VTI interfuse S) were analysed retrospectively with one-year follow-up. Lumbar sagittal parameters were collected preoperatively, postoperatively and at one year follow-up. Cage subsidence, fusion rate, screw loosening and proportion of endplate coverage were assessed in computed tomography scan.Results: 20 patients (age 66 ± 10 years, 65% female, BMI 28 ± 5 kg/m2) with a total of 37 fusion levels were included. 15 patients had degenerative spondylosis and 5 patients had degenerative scoliosis. The cages covered >60% of the vertebral body diameters. Lumbar lordosis angle and segmental disc angle increased from 45.2 ± 14.5 and 7.3 ± 3.6 to 52.7 ± 9.1 and 10.5 ± 3.5 (p = 0.029 and 0.0002) postoperatively for each parameter respectively without loss of correction at one year follow up. One case of deep postoperative infection occurred (5%). No cage subsidence occurred. No non-union or screw loosening occurred.Conclusions: The modular TLIF cage was safe with regard to subsidence and union-rate. It restored and maintained lumbar lordosis angle, segmental disc angle and disc height, which can be attributed to the large footprint of this modular cage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.