Although previous in vitro studies found a change in corneal rigidity, this study found no significant change in CH or CHF measured by biomechanical waveform analysis.
Neither author has a financial or proprietary interest in any material or method mentioned.
Implantation of the Artisan PIOL is effective in improving visual acuity in patients with stable keratoconus. Long-term safety remains to be established as no postoperative endothelial cell counts were performed.
Our study demonstrated the superiority of AFG to NS in saving operating time and elimination of recurrence without any complications in pterygium surgery. AFG can obviate the need for suturing and increases the viability of tissue flaps. Additional studies are necessary to determine the long-term effects considering factors such as primary or recurrent status of pterygium, age and sex of patient, dose and duration of treatment for mitomycin C.
PurposeThe aim of this study was to analyze and compare corneal endothelial cell morphology and characteristics in bilateral keratoconus (KCN) patients with unilateral Vogt's striae.MethodsFifty patients aged 20–38 years were recruited in this cross-sectional contralateral eye study. In this study, corneal endothelial cell parameters were evaluated in patients with bilateral KCN and unilateral Vogt's striae using the Topcon SP2000P specular microscope (Topcon, Tokyo, Japan).ResultsIn the current study, there were no significant differences in corneal endothelial cell parameters including endothelial cell density (ECD), hexagonal cell ratio (HEX), and coefficient of variance of cell size (CV) between the KCN groups with and without Vogt's striae, [(2968.34 ± 276.65 vs. 2980.05 ± 253.30, P = 0.618), (51.88 ± 13.57 vs. 53.24 ± 9.31, P = 0.658), and (32.50 ± 5.40 vs. 32.97 ± 4.07, P = 0.467), respectively]. Also, among study groups with and without Vogt's striae, ECD did not correlate with anterior chamber depth (ACD) [(P = 0.564, r = 0.09), (P = 0.219, r = −0.18), respectively], maximum keratometry (Kmax) [(P = 0.215, r = 0.18), (P = 0.898, r = 0.02), respectively], and central corneal thickness (CCT) [(P = 0.989, r = −0.02), (P = 0.643, r = −0.07), respectively].Our results showed significant differences in corrected and uncorrected distance visual acuity (UDVA), cycloplegic refractive error components (calculated by vectorial analysis), CCT, and Kmax between two study groups (all P < 0.05) except for J45 (Jackson cross cylinder, axes at 45 and 135°) (P = 0.131).ConclusionsWe were not able to find the statistically significant differences in ECD, HEX, and CV between KCN eyes with and without Vogt's striae. Despite clinical and tomographic results, it seems that Vogt's striae cannot cause deterioration in the corneal endothelial morphology.
PurposeTo evaluate and compare corneal hysteresis (CH) and corneal resistance factor (CRF) in pellucid marginal degeneration (PMD), keratoconus (KCN), and normal eyes using the Ocular Response Analyzer (ORA).MethodsIn this retrospective study, corneal biomechanical parameters were measured in patients with PMD (n = 102) and KCN (n = 202) and normal subjects (n = 208) using the ORA. Data, including full patient history as well as the results of refraction, slit-lamp biomicroscopy, Pentacam HR (Oculus), and ORA (Reichert; Buffalo, New York, USA), were collected from medical records. Also, the data of only one eye per individual were selected for the analysis. The inclusion criteria for PMD and KCN groups were a reliable diagnosis of these ectatic disorders based on the clinical and corneal tomographic findings. CH, CRF, CH–CRF, intraocular pressure (IOP) measurements were assessed for each subject. Data were analyzed with SPSS and MedCalc using the ANOVA, Pearson Correlation, and receiver operating characteristic (ROC) curve analysis.ResultsThe mean CH was 8.91 mmHg ± 1.05 [standard deviation (SD)], 8.43 ± 0.78, and 10.89 ± 1.08 in the PMD, KCN, and normal group, respectively. Also, the mean CRF was 8.21 ± 1.35, 7.19 ± 1.11, and 10.69 ± 1.41 in the PMD, KCN, and normal group, respectively. ANOVA showed differences in the mean CH, CRF, and CH–CRF between three groups (P < 0.001). Also, ROC curve analysis showed the cut-off points ≤9.5, ≤9.5, and >1.3 mmHg for CH, CRF, and CH–CRF in the PMD group, respectively. For biomechanical parameters in PMD eyes, CRF had the highest sensitivity (75.49%) while the greatest area under the ROC curve (AUC) was seen for CH (0.903). Moreover, central corneal thickness (CCT) showed no correlation with CH (P = 0.30, r = −0.104) or CRF (P = 0.75, r = 0.033) in the PMD group.ConclusionsThis study presented the values of corneal biomechanics for PMD using the ORA. The results of the ORA were markedly different between PMD, KCN, and normal eyes.
PurposeThe aim of this study was to evaluate and compare tomographic and biometric characteristics measured by the corneal tomography and ocular biometry in bilateral keratoconus (KCN) patients with and without corneal Vogt’s striae.MethodsNinety-two eyes of 46 subjects with a reliable diagnosis of bilateral KCN with unilateral Vogt’s striae were enrolled in this cross-sectional contralateral eye study. In addition to refraction (calculated by vectorial analysis) and visual acuity, corneal tomographic measurements were obtained by the Pentacam (Scheimpflug-based anterior segment tomography). Also, ocular biometric characteristics were evaluated using the Ocuscan® RxP (ultrasound biometer). The KCN eyes were categorized into two groups, including eyes with Vogt’s striae and eyes without Vogt’s striae.ResultsOur results showed significant differences in the sphere, cylinder, spherical equivalent, J0, corrected and uncorrected distance visual acuity, flat, steep and maximum keratometry, anterior chamber depth (ACD), and central corneal thickness (CCT) between the two groups (all P<0.001). The eyes without Vogt’s striae had a shorter ACD measured by the Pentacam and biometer. There were no differences in axial length (AL) and vitreous length (VL) between the two groups (all P>0.05). Also, there was poor agreement between the measurements of the Pentacam and ultrasound biometer for ACD in the study groups.ConclusionCorneal tomographic and ocular biometric measurements showed significant differences between KCN eyes with and without Vogt’s striae except for AL and VL. These differences should be noticed in clinical evaluations and treatment of KCN patients.
PurposeTo investigate the effects of religious fasting during the month of Ramadan on intraocular pressure (IOP), refractive error, corneal tomography and biomechanics, ocular biometry, and tear film layer properties.MethodsThis prospective study was carried out one week before and in the last week of Ramadan. Ninety-four eyes of 94 healthy adult volunteers (54 males and 40 females) with a mean ± SD age of 35.12 ± 9.07 were enrolled in this study. Patients with any systemic disorder, ocular disease, or a history of previous surgery were excluded. Corneal tomography and biomechanics, ocular biometry, IOP, refractive error, and tear break up time (TBUT) were evaluated in non-fasting and fasting periods by the Pentacam (Oculus), Corvis ST (Oculus), IOL Master (Carl Zeiss), computerized tonometer (Topcon CT-1/CT-1P), auto kerato-refractometer (Topcon KR-1), and Keratograph 5M (Oculus), respectively.ResultsThere was no significant difference in the central corneal thickness (CCT) between the study groups (P = 0.123) using the Pentacam while the Corvis ST showed a significant difference in all participants (P < 0.0001). Moreover, the peak distance (distance of the two surrounding peaks of the cornea at the highest concavity) of male and female participants showed a significant difference between the fasting and non-fasting groups (P = 0.002). The anterior chamber depth (ACD) using the Pentacam decreased in the male group (P = 0.004) in the fasting period. During the fasting period, computerized tonometer showed a decrease in IOP only in males in comparison to the non-fasting group (P = 0.018) while the Corvis ST showed decreased IOP in all participants (P < 0.0001). The steep keratometry (K2) in the corneal posterior surface appeared to be different in males between the study groups (P = 0.034). We were unable to show any significant difference in other ocular parameters between fasting and non-fasting periods.ConclusionThis study showed that ACD, IOP, CCT, and peak distance were different between fasting and non-fasting groups while no difference was observed in other ocular parameters. Interpretations of these significant differences should be considered in the clinical setting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.